Abstract
The voltage closed-loop field-weakening scheme (VCFS) is an effective method to achieve the maximum output torque for induction motor (IM) high-speed drives. However, the cross-coupling between the inner current and outer voltage loops lead to system performance deterioration. To address this problem, this paper proposed a unified complex vector field-weakening control. First, the inherent coupling problem in VCFS is analyzed based on the double closed-loop structure. On this basis, a complex vector structure is designed to unify the inner current and outer voltage loops, following with a decoupled criterion for controller coefficient selection. Compared with the conventional VCFS, the studied scheme can eliminate the natural complex vector zero in the voltage loop, leading to current ripple and voltage overshoot reduction. The experimental results confirm the effectiveness of the investigated scheme.
Funding Information
  • National Natural Science Foundation of China (51690182, 51807038)
  • Natural Science Foundation of Heilongjiang Province (YQ2020E018)
  • China Postdoctoral Science Foundation (2018M630354, 2019T120267)
  • Postdoctoral Foundation of Hei Long Jiang Province (LBH-Z18097)

This publication has 24 references indexed in Scilit: