Real-world safety and efficacy of WATCHMAN LAA closure at one year in patients on dual antiplatelet therapy: results of the DAPT subgroup from the EWOLUTION all-comers study
Authors:
- Hüseyin InceHIHüseyin Ince
- Stephan KischeSKStephan Kische
- Thomas SchmitzTSThomas Schmitz
- Felix MeinckeFMFelix Meincke
- Boris SchmidtBSBoris Schmidt
- David FoleyDFDavid Foley
- Timothy R. BettsTBTimothy R. Betts
- Marek GrygierMGMarek Grygier
- Alexey V. ProtopopovAPAlexey V. Protopopov
- Kenneth M. SteinKSKenneth M. Stein
- Lucas V.A. BoersmaLBLucas V.A. Boersma
- 1 April 2018
- journal article
- research article
- Published by Europa Digital & Publishing in EuroIntervention
- Vol. 13 (17) , 2003-2011
Abstract
The study aimed to confirm the efficacy and safety of WATCHMAN LAA closure in atrial fibrillation patients unsuitable for oral anticoagulation. The EWOLUTION registry prospectively collects all clinical data on 1,005 European patients implanted with a WATCHMAN device. Following the procedure, 605 patients (60.2%) received dual antiplatelet therapy according to the local standard; DAPT was discontinued in 85% of patients within one year. CHA2DS2-VASc and HAS-BLED scores were 4.61.6 and 2.41.2, respectively. The periprocedural SAE rate was 3.3% (2.0% major adverse cardiac events), mostly resolving without sequelae. Device embolisation or pericardial effusion occurred in one (0.2%) and two (0.3%) patients, respectively. TEE (median 62 days post implant, IQR: 47-97) confirmed effective sealing (no leak >5 mm) in 99.2% of patients. Device thrombus was present in 22 patients (4.0%), one patient developed a stroke. One-year mortality in the DAPT group was 9.6% (N=58) reflecting the advanced age and comorbidities in this population. The ischaemic stroke rate at one year was 1.4% (expected based on CHA2DS2-VASc: 7.5%), none fatal. The major bleeding rate was 2.5%, or 2.1% excluding periprocedural events (expected rate on VKA based on HAS-BLED: 5.1%). LAA closure with the WATCHMAN device followed by DAPT therapy in a high-risk patient population is safe. At one year, the intervention is associated with a substantial risk reduction regarding ischaemic stroke and major bleeding compared to the expected rate based on CHA2DS2-VASc and HAS-BLED scores.Keywords
This publication has 18 references indexed in Scilit:
- Direct Comparison of Dabigatran, Rivaroxaban, and Apixaban for Effectiveness and Safety in Nonvalvular Atrial FibrillationChest, 2016
- Percutaneous left atrial appendage occlusion: the Munich consensus document on definitions, endpoints and data collection requirements for clinical studiesEuroIntervention, 2016
- Implant success and safety of left atrial appendage closure with the WATCHMAN device: peri-procedural outcomes from the EWOLUTION registryEuropean Heart Journal, 2016
- EWOLUTION: Design of a registry to evaluate real‐world clinical outcomes in patients with AF and high stroke risk‐treated with the WATCHMAN left atrial appendage closure technologyCatheterization and Cardiovascular Interventions, 2015
- Percutaneous Left Atrial Appendage Closure vs Warfarin for Atrial FibrillationJAMA, 2014
- Left Atrial Appendage Closure With the Watchman Device in Patients With a Contraindication for Oral AnticoagulationJACC, 2013
- Efficacy and safety of apixaban compared with warfarin according to patient risk of stroke and of bleeding in atrial fibrillation: a secondary analysis of a randomised controlled trialThe Lancet, 2012
- 2012 focused update of the ESC Guidelines for the management of atrial fibrillationEuropean Heart Journal, 2012
- Evaluation of risk stratification schemes for ischaemic stroke and bleeding in 182 678 patients with atrial fibrillation: the Swedish Atrial Fibrillation cohort studyEuropean Heart Journal, 2012
- Comparative Validation of a Novel Risk Score for Predicting Bleeding Risk in Anticoagulated Patients With Atrial FibrillationJACC, 2011