Open Reduction and Internal Fixation of Unstable Distal Radius Fractures: Results Using the Trimed Fixation System
Authors:
- Sherice BahlerSBSherice Bahler
- 1 September 2002
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 16 (8) , 578-585
Abstract
The purpose of this study was to evaluate the early results of patients with displaced and unstable distal radius fractures treated with fragment-specific fixation. Prospective and consecutive. Private orthopaedic practice. Twenty-five patients with 27 fractures with an average follow-up of 29 months (range 24–36 months) treated with fragment-specific fixation for unstable radius fractures. Clinical and radiographic examination. Disabilities of the arm, hand, and shoulder and patient-rated wrist evaluation outcome measures. Patients had an average 61° of dorsiflexion and 54° of palmarflexion at the wrist. Twenty-five fractures healed in acceptable alignment, with one loss of reduction and one patient death. Mean ± standard deviation DASH score was 17 ± 18, and PRWE score was 19 ± 22. Unstable distal radius fractures can be reliably and anatomically reduced and stabilized using fragment-specific fixation. Fixation of markedly comminuted fractures is secure enough to allow immediate motion and does not require casting or external fixation. Preliminary clinical and radiographic results are excellent, and patient satisfaction is high. Anatomic reduction with early motion can be achieved in a routine fashion on unstable distal radius fractures using the described technique.Keywords
This publication has 27 references indexed in Scilit:
- Treatment of unstable distal radius fractures with cancellous allograft and external fixationThe Journal of Hand Surgery, 1999
- Complications in internal fixation of the distal radiusThe Journal of Hand Surgery, 1998
- Complications of the AO/ASIF titanium distal radius plate system (π plate) in internal fixation of the distal radius: A brief reportThe Journal of Hand Surgery, 1998
- Prospective multicenter trial of a plate for dorsal fixation of distal radius fracturesThe Journal of Hand Surgery, 1997
- Factors affecting functional outcome of displaced intra-articular distal radius fracturesThe Journal of Hand Surgery, 1994
- Fractures of the Distal End of the Radius in Young Adults: A 30-Year Follow-UpJournal of Hand Surgery (European Volume), 1993
- Open reduction and internal fixation for distal radius fracturesThe Journal of Hand Surgery, 1992
- Percutaneous and Limited Open Reduction of the Articular Surface of the Distal RadiusJournal of Orthopaedic Trauma, 1991
- Treatment of displaced articular fractures of the radiusThe Journal of Hand Surgery, 1991
- Open reduction and internal fixation of comminuted, intraarticular fractures of the distal radiusThe Journal of Hand Surgery, 1990