Abstract
Transcatheter aortic valve implantation is a minimal-invasive intervention for implanting prosthetic valves in patients with aortic stenosis. Accurate automated sizing for planning and patient selection is expected to reduce adverse effects such as paravalvular leakage and stroke. Segmentation of the aortic root in CTA is pivotal to enable automated sizing and planning. We present a fully automated segmentation algorithm to extract the aortic root from CTA volumes consisting of a number of steps: first, the volume of interest is automatically detected, and the centerline through the ascending aorta and aortic root centerline are determined. Subsequently, high intensities due to calcifications are masked. Next, the aortic root is represented in cylindrical coordinates. Finally, the aortic root is segmented using 3D normalized cuts. The method was validated against manual delineations by calculating Dice coefficients and average distance error in 20 patients. The method successfully segmented the aortic root in all 20 cases. The mean Dice coefficient was 0.95 ± 0.03, and the mean radial absolute error was 0.74 ± 0.39 mm, where the interobserver Dice coefficient was 0.95 ± 0.03 and the mean error was 0.68 ± 0.34 mm. The proposed algorithm showed accurate results compared to manual segmentations.Keywords
This publication has 21 references indexed in Scilit:
- Complete valvular heart apparatus model from 4D cardiac CTMedical Image Analysis, 2012
- 3D segmentation of abdominal aorta from CT-scan and MR imagesComputerized Medical Imaging and Graphics, 2012
- Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo SurgeryNew England Journal of Medicine, 2010
- Transapical transcatheter aortic valve implantation: Follow-up to 3 yearsThe Journal of Thoracic and Cardiovascular Surgery, 2010
- Factors associated with cardiac conduction disorders and permanent pacemaker implantation after percutaneous aortic valve implantation with the CoreValve prosthesisAmerican Heart Journal, 2010
- An image-based modeling framework for patient-specific computational hemodynamicsMedical & Biological Engineering & Computing, 2008
- Transcatheter valve implantation for patients with aortic stenosis: a position statement from the European Association of Cardio-Thoracic Surgery (EACTS) and the European Society of Cardiology (ESC), in collaboration with the European Association of Percutaneous Cardiovascular Interventions (EAPCI)European Heart Journal, 2008
- Percutaneous Implantation of the CoreValve Self-Expanding Valve Prosthesis in High-Risk Patients With Aortic Valve DiseaseCirculation, 2006
- Aortic dimensions and the risk of dissectionHeart, 2005
- Normalized cuts and image segmentationIEEE Transactions on Pattern Analysis and Machine Intelligence, 2000