Efficacy of Computer-Aided Detection System and Thin-Slab Maximum Intensity Projection Technique in the Detection of Pulmonary Nodules in Patients With Resected Metastases
Authors:
- Jin Mo GooJGJin Mo Goo
- Jeong Won LeeJLJeong Won Lee
- Chang Hyun KangCKChang Hyun Kang
- Hyun Ju LeeHLHyun Ju Lee
- Chang Hyun LeeCLChang Hyun Lee
- Chang Min ParkCPChang Min Park
- Jung-Gi ImJIJung-Gi Im
- 1 February 2009
- journal article
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 44 (2) , 105-113
Abstract
To evaluate the efficacy of the computer-aided detection (CAD) system and thin-slab maximum intensity projection (MIP) technique in the detection of pulmonary nodules at multidetector computed tomography (CT) in patients who underwent metastatectomy.This retrospective study was approved by the institutional review board and patients' informed consent was waived. Forty-nine consecutive patients who underwent pulmonary metastatectomy were enrolled. Four chest radiologists analyzed preoperative 1-mm section CT images and recorded the locus of each nodule candidate. Afterward, they reevaluated the images once using CAD software and once with thin-slab MIP given the results of 1-mm section CT alone. The reference standard for nodule presence was established by a consensus panel and pathologic records for malignant nodules.A total of 514 nodules were identified by a consensus panel. Of 212 nodules surgically removed, 121 nodules were malignant. The sensitivity of each observer in detecting malignant nodules with thin-section CT scans alone was 91%, 88%, 87%, and 86% for observers A- to D, respectively. With CAD, sensitivity increased significantly to 95%, 95%, 94%, and 95% (P< 0.05 for observer B-D), and using MIP increased to 94%, 96%, 91%, and 92% (P < 0.05 for observer B-D), respectively. There were no significant differences in sensitivity between CAD and MIP for the detection of malignant nodules. The average number of false-positive findings per patient was 0.8 with thin-section CT alone, 1.1 with CAD, and 1.4 with MIP.In candidates for metastatectomy, reading with the aid of either CAD or MIP significantly improved the detection of malignant nodules compared with using thin-section CT alone.Keywords
This publication has 34 references indexed in Scilit:
- Surgical Resection for Multifocal (T4) Non-Small Cell Lung Cancer: Is the T4 Designation Valid?The Annals of Thoracic Surgery, 2007
- Metastatectomy prior to Immunochemotherapy for Metastatic Renal Cell CarcinomaUrologia Internationalis, 2006
- Surgical treatment for metastatic malignancies. Pulmonary metastasis: indications and outcomesInternational Journal of Clinical Oncology, 2004
- Role of metastasectomy in the management of thyroid carcinoma: The NIH experienceJournal of Surgical Oncology, 2002
- Thoracic metastasectomy in thyroid malignanciesThe Annals of Thoracic Surgery, 2001
- The surgical management of pulmonary metastasis: current conceptsSurgical Oncology, 2001
- Surgical Treatment of Pulmonary MetastasesSurgical Oncology Clinics of North America, 1999
- Midterm Results of Thoracoscopic Surgery for Pulmonary Metastases Especially from Colorectal CancersJournal of Laparoendoscopic & Advanced Surgical Techniques, 1998
- PULMONARY RESECTION FOR METASTATIC BREAST CANCERAnz Journal of Surgery, 1997
- Surgery and Chemotherapy for Pulmonary Metastases: Long-Term Results from a Combined Modality ApproachThe Thoracic and Cardiovascular Surgeon, 1991