The purpose of this article was to determine whether a coralline hydroxyapatite bone graft substitute (Pro Osteon 500) adequately repaired bone defects during complex acetabular revisions. Coralline hydroxyapatite has great potential as a bone graft substitute: its uniform, highly interconnected, 3-dimensional porosity can be completely infiltrated by bone; and because it is manufactured from marine coral, concerns with cadaver bone are alleviated. The 17 patients composing this retrospective study had significant preoperative defects (15 type 2, two type 3). Follow-up ranged from 2 years to 7 years and 9 months. At last follow-up, no cups had been re-revised, but 1 had failed. This cup migrated 10° and 21.24 mm (3B preoperative defect). Three other cups had complete radiolucencies but were stable and did not meet our criteria for loose (lines >2 mm in all 3 zones). All patients' most recent radiographs showed evidence of bone incorporation (absence or loss of radiolucency at bone-graft junction) and ingrowth (trabecularization) into the coralline hydroxyapatite grafts. Eight patients' early radiographs revealed radiolucencies between bone and portions of the graft. Of these, 4 patients' radiolucencies completely resolved, 2 partially resolved, and 2 remained unchanged at last follow-up. Trabecularization was seen abutting the cup (evidence of bone ingrowth into the cup) on 9 patients' radiographs. Increased graft density, which may indicate that a graft has not revascularized, was observed on the radiographs of 3 patients, 1 being the patient whose cup had failed and the others being 2 of the 3 patients with complete radiolucencies. Graft resorption was not observed.