Robust gesture recognition based on attention-deep fast convolutional neural network and surface electromyographic signals
Open Access
- 10 July 2024
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Neuroscience
- Vol. 18, 1306047
Abstract
The surface electromyographic (sEMG) signals reflect human motor intention and can be utilized for human-machine interfaces (HMI). Comparing to the sparse multi-channel (SMC) electrodes, the high-density (HD) electrodes have a large number of electrodes and compact space between electrodes, which can achieve more sEMG information and have the potential to achieve higher performance in myocontrol. However, when the HD electrodes grid shift or damage, it will affect gesture recognition and reduce recognition accuracy. To minimize the impact resulting from the electrodes shift and damage, we proposed an attention deep fast convolutional neural network (attention-DFCNN) model by utilizing the temporary and spatial characteristics of high-density surface electromyography (HD-sEMG) signals. Contrary to the previous methods, which are mostly base on sEMG temporal features, the attention-DFCNN model can improve the robustness and stability by combining the spatial and temporary features. The performance of the proposed model was compared with other classical method and deep learning methods. We used the dataset provided by The University Medical Center Göttingen. Seven able-bodied subjects and one amputee involved in this work. Each subject executed nine gestures under the electrodes shift (10 mm) and damage (6 channels). As for the electrodes shift 10 mm in four directions (inwards; onwards; upwards; downwards) on seven able-bodied subjects, without any pre-training, the average accuracy of attention-DFCNN (0.942 0.04) is significantly higher than LSDA (0.910 0.04, p < 0.01), CNN (0.920 0.05, p < 0.01), TCN (0.840 0.07, p < 0.01), LSTM (0.864 0.08, p < 0.01), attention-BiLSTM (0.852 0.07, p < 0.01), Transformer (0.903 0.07, p < 0.01) and Swin-Transformer (0.908 0.09, p < 0.01). The proposed attention-DFCNN algorithm and the way of combining the spatial and temporary features of sEMG signals can significantly improve the recognition rate when the HD electrodes grid shift or damage during wear.
Keywords
This publication has 22 references indexed in Scilit:
- Surface Electromyography as a Natural Human–Machine Interface: A ReviewIEEE Sensors Journal, 2022
- Advances and Disturbances in sEMG-Based Intentions and Movements Recognition: A ReviewIEEE Sensors Journal, 2021
- sEMG-Based Human-in-the-Loop Control of Elbow Assistive Robots for Physical Tasks and Muscle Strength TrainingIEEE Robotics and Automation Letters, 2020
- Efficient correction of armband rotation for myoelectric-based gesture control interfaceJournal of Neural Engineering, 2020
- Surface-Electromyography-Based Gesture Recognition by Multi-View Deep LearningIEEE Transactions on Biomedical Engineering, 2019
- Programming by Demonstration Using the Teleimpedance Control Scheme: Verification by an sEMG-Controlled Ball-Trapping RobotIEEE Transactions on Industrial Informatics, 2018
- Recent advances in convolutional neural networksPattern Recognition, 2018
- Gesture recognition by instantaneous surface EMG imagesScientific Reports, 2016
- Improving Myoelectric Pattern Recognition Robustness to Electrode Shift by Changing Interelectrode Distance and Electrode ConfigurationIEEE Transactions on Biomedical Engineering, 2011
- A robust, real-time control scheme for multifunction myoelectric controlIEEE Transactions on Biomedical Engineering, 2003