The effects of calcium phosphate deposition upon corrosion of CoCr alloys and the potential for implant failure
- 8 August 2005
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 75A (2) , 365-373
Abstract
Physical wear of orthopedic implants is inevitable. CoCr metal samples, typically used in joint reconstruction, corrode rapidly after removal of the protective oxide layer. The behavior of CoCr pellets immersed in human serum, fetal bovine serum (FBS), synovial fluid, and water were studied using time‐of‐flight secondary ion mass spectroscopy (ToF‐SIMS). The differences in the corrosive nature of human serum, FBS, synovial fluid, and water after 5 days immersion were highlighted by the oxide/hydroxide layer, which was, respectively, 25, 10, 1.5, and 3–3.5 nm thick. The thickness of calcium phosphate deposit from human serum, FBS, and synovial fluid was, respectively, 30, 20, and 2 nm. Co and Cr ions migrated from the bulk metal surface and were trapped in the serum deposits, where chromium existed as oxides, hydroxides, and phosphates, whereas the cobalt chemistry was dominated only by phosphates and hydroxides. This may account for the composition of wear debris from CoCr orthopedic implants, which are predominantly hydroxyphosphate compounds. From the literature, proteoglycans, pyrophosphates, phospholipids, lubricin, and superficial zone protein (SZP) have been identified as possible causes for the insignificant deposit of calcium phosphate from synovial fluid. Circulation of these compounds around the whole implant may inhibit calcium phosphate deposition and therefore contribute to osteolysis. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res, 2005Keywords
This publication has 38 references indexed in Scilit:
- Effect of synovial fluid, phosphate‐buffered saline solution, and water on the dissolution and corrosion properties of CoCrMo alloys as used in orthopedic implantsJournal of Biomedical Materials Research Part A, 2005
- Composition of joint fluid in patients undergoing total knee replacement and revision arthroplasty: correlation with flow propertiesBiomaterials, 2004
- Size, shape, and composition of wear particles from metal–metal hip simulator testing: Effects of alloy and number of loading cyclesJournal of Biomedical Materials Research Part A, 2003
- Characterization of chemical inhomogeneity in plasma-sprayed hydroxyapatite coatingsBiomaterials, 2003
- A Rat Model for Testing Pharmacologic Treatments of Pressure-Related Bone LossClinical Orthopaedics and Related Research, 2003
- Calcium Phosphate Phase Identification Using XPS and Time-of-Flight Cluster SIMSAnalytical Chemistry, 1998
- Migration, Particles, and Fluid PressureClinical Orthopaedics and Related Research, 1998
- Role of alveolar macrophage lysosomes in metal detoxificationMicroscopy Research and Technique, 1997
- Auger electron spectroscopic studies of stainless‐steel implantsJournal of Biomedical Materials Research, 1985
- The passivation of alloys on titanium basesElectrochimica Acta, 1974