Investigation of Optimum Insulation Thickness in The Wall With Air-Cavity and The Environmental Analysis
- 24 March 2026
- journal article
- Published by Bitlis Eren Universitesi Fen Bilimleri Dergisi in Bitlis Eren Üniversitesi Fen Bilimleri Dergisi
- Vol. 15 (1) , 228-244
Abstract
Making energy efficient designs in building walls can be a solution to reduce increasing building energy consumption and thus environmental pollution. By using insulation and energy efficient building materials, the heating and cooling loads of buildings and therefore fuel consumption and environmental pollution can be significantly reduced. Therefore, this paper goals to evaluate the thermal, economic and environmental effects of walls with air-cavities by considering different wall orientations. The study uses a numerical method called the implicit finite difference procedure to compute annual transmission loads for walls that have and haven't air-cavities during the summer and winter seasons in Elazığ province of Turkey. The conclusions show that the annual cooling and heating loads decline by about 31% for all wall orientations when a 2.5 cm air-cavity is positioned in the center of an uninsulated concrete wall. The study also shows that the effect of the air-cavity on heat transmission loads declines as insulation thickness rises. Additionally, walls incorporating air cavities were analyzed to determine their annual average time lag and decrement factor. To identify the optimal insulation thickness, a cost analysis was conducted using annual transmission loads calculated under dynamic thermal conditions. The findings indicate that the most effective insulation thicknesses for walls with air cavities are 12.4 cm for south-facing orientations, 13.2 cm for north-facing, and 13.4 cm for east- and west-facing orientations. When these optimal values are applied across all orientations, the annual heating energy, fuel consumption, and associated emissions are reduced by 87.3%, 87.9%, and 88.0%, respectively.Keywords
This publication has 42 references indexed in Scilit:
- Impact of the insulation materials’ features on the determination of optimum insulation thicknessInternational Journal of Energy and Environmental Engineering, 2014
- Effect of thermal bridges on transmission loads and thermal resistance of building walls under dynamic conditionsApplied Energy, 2012
- Effect of thermal mass on performance of insulated building walls and the concept of energy savings potentialApplied Energy, 2012
- Improving thermal performance of building walls by optimizing insulation layer distribution and thickness for same thermal massApplied Energy, 2011
- Effect of wall orientation on the optimum insulation thickness by using a dynamic methodApplied Energy, 2011
- A study on optimum insulation thickness in walls and energy savings in Tunisian buildings based on analytical calculation of cooling and heating transmission loadsApplied Energy, 2011
- The usage of air gap in the composite wall for energy saving and air pollutionEnvironmental Progress & Sustainable Energy, 2010
- A study on optimum insulation thicknesses of external walls in hot summer and cold winter zone of ChinaApplied Energy, 2009
- Optimization of insulation thickness for external walls using different energy-sourcesApplied Energy, 2006
- Effect of electricity tariff on the optimum insulation-thickness in building walls as determined by a dynamic heat-transfer modelApplied Energy, 2005