Predicting Indoor Temperature Distribution Based on Contribution Ratio of Indoor Climate (CRI) and Mobile Sensors
Open Access
Abstract
In practical building control, quickly obtaining detailed indoor temperature distribution is necessary for providing satisfying personal comfort and improving building energy efficiency. The aim of this study is to propose a fast prediction method for indoor temperature distribution without knowing the thermal boundary conditions in practical applications. In this method, the index of contribution ratio of indoor climate (CRI), which represents the independent contribution of each heat source to the temperature distribution, has been combined with the air temperature collected by one mobile sensor at the height of the working area. Based on a typical office model, the effectiveness of using mobile sensors was discussed, and the influence of its acquisition height and acquisition distance on the prediction accuracy was analyzed as well. The results showed that the proposed prediction method was effective. When the sensors fixed on the wall were used to predict the indoor temperature distribution, the maximum average relative error was 27.7%, whereas when the mobile sensor was used to replace the fixed sensors, the maximum average relative error was 4.8%. This indicates that using mobile sensors with flexible acquisition location can help promote both reliability and accuracy of temperature prediction. In the human activity area, data from a set of mobile sensors were used to predict the temperature distribution at four heights. The prediction accuracy was 2.1%, 2.1%, 2.3%, and 2.7%, respectively. However, the influence of acquisition distance of mobile sensors on prediction accuracy cannot be ignored. The distance should be large enough to disperse the distribution of the acquisition points. Due to the influence of airflow, some distance between the acquisition points and the room boundaries should be given.Keywords
Funding Information
- National Natural Science Foundation of China (Grant No. 5190080465)
- Special fund of Beijing Key Laboratory of Indoor Air Quality Evaluation and Control (No.BZ0344KF20-05)
- Joint Research Project of the Wind Engineering Research Center, Tokyo Polytechnic University (MEXT (Japan) Promotion of Distinctive Joint Research Center Program Grant Number: JPMXP0619217840, JURC grant number 21212012)
This publication has 37 references indexed in Scilit:
- Building energy simulation considering spatial temperature distribution for nonuniform indoor environmentBuilding and Environment, 2013
- On the construction and use of linear low-dimensional ventilation modelsIndoor Air, 2012
- Development of new indices to assess the contribution of moisture sources to indoor humidity and application to optimization design: Proposal of CRI(H) and a transient simulation for the prediction of indoor humidityBuilding and Environment, 2011
- Control of indoor thermal environment based on concept of contribution ratio of indoor climateBuilding Simulation, 2010
- Thermal simulation: Response factor analysis using three-dimensional CFD in the simulation of air conditioning controlBuilding Simulation, 2010
- Fast and informative flow simulations in a building by using fast fluid dynamics model on graphics processing unitBuilding and Environment, 2010
- CALCULATION METHOD OF CONTRIBUTION RATIO OF INDOOR CLIMATE (CRI) BY MEANS OF SETTING A UNIFORM HEAT SINK IN NATURAL CONVECTION AIR FLOW FIELDJournal of Environmental Engineering (Transactions of AIJ), 2010
- Fast simulation of temperature distribution in air conditioned rooms by using proper orthogonal decompositionBuilding and Environment, 2009
- Accessibility: A New Concept to Evaluate Ventilation Performance in a Finite Period of TimeIndoor and Built Environment, 2004
- The National Human Activity Pattern Survey (NHAPS): a resource for assessing exposure to environmental pollutantsJournal of Exposure Science & Environmental Epidemiology, 2001