Peripheral blood eosinophils and other non‐invasive biomarkers can monitor treatment response in eosinophilic oesophagitis
Authors:
Open Access
- 27 August 2015
- journal article
- research article
- Published by Wiley in Alimentary Pharmacology & Therapeutics
- Vol. 42 (9) , 1122-1130
Abstract
Summary: Background: Monitoring of the treatment response in eosinophilic oesophagitis (EoE) requires structured endoscopical and histological examination of the oesophagus. Less invasive methods would be highly desirable.Aim: To evaluate the utility of several EoE‐associated blood and serum markers in order to non‐invasively monitor the response to treatment with swallowed topical corticosteroids in adult EoE patients.Methods: In a randomised, controlled double‐blind trial blood samples of EoE patients (n = 69) were collected at baseline and after 14 days of treatment with budesonide (n = 51) or placebo (n = 18) respectively. Absolute blood eosinophil count (AEC) as well as serum levels of CCL‐17, CCL‐18, CCL‐26, eosinophil‐cationic‐protein (ECP) and mast cell tryptase (MCT) were determined and correlated with oesophageal eosinophil density and with symptom and endoscopy scores.Results: Histological remission, defined as mean number of 2 hpf at end‐of‐treatment, was achieved in 98% of the budesonide and 0% of the placebo recipients. AEC [380.2 vs. 214.7/mm3 (P = 0.0001)], serum‐CCL‐17 [294.3 vs. 257.9 pg/mL (P = 0.0019)], ‐CCL‐26 [26.7 vs. 16.2 pg/mL (P = 0.0058)], ‐ECP [45.5 ± 44.7 vs. 27.5 ± 25.0 μg/L (P = 0.0016)] and ‐MCT [5.3 ± 2.9 vs. 4.5 ± 2.6 μg/L (P = 0.0019)] significantly decreased under budesonide but not under placebo. AEC significantly correlated with oesophageal eosinophil density before (r = 0.28, P = 0.0236) and after (r = 0.42, P = 0.0004) budesonide treatment. In ROC‐AUC analyses post‐treatment values of AEC were significantly associated with histological remission (ROC‐AUC 0.754; 95% CI: 0.617–0.891; P = 0.0003).Conclusions: The budesonide‐induced treatment response in EoE is mirrored by several blood and serum markers, and the absolute blood eosinophil count is the most valuable as it shows correlation with the oesophageal eosinophil density.Keywords
Funding Information
- Dr Falk pharma
- AstraZeneca
- Covidien
- Falk Foundation
- Malesci
- Olympus
- Pentax
- Shire
- Icon plc, Dublin, Ireland
This publication has 39 references indexed in Scilit:
- The oesophageal string test: a novel, minimally invasive method measures mucosal inflammation in eosinophilic oesophagitisGut, 2012
- Exploring Potential Noninvasive Biomarkers in Eosinophilic Esophagitis in ChildrenJournal of Pediatric Gastroenterology and Nutrition, 2011
- Eosinophilic esophagitis: Updated consensus recommendations for children and adultsJournal of Allergy and Clinical Immunology, 2011
- Blood tests and histological correlates in children with eosinophilic oesophagitisActa Paediatrica, 2011
- Involvement of mast cells in eosinophilic esophagitisJournal of Allergy and Clinical Immunology, 2010
- Effect of the inhaled corticosteroid mometasone on small airway patency in patients with asthmaAllergy and Asthma Proceedings, 2009
- Potential of Blood Eosinophils, Eosinophil-Derived Neurotoxin, and Eotaxin-3 as Biomarkers of Eosinophilic EsophagitisClinical Gastroenterology and Hepatology, 2006
- Clinical presentation of patients with eosinophilic inflammation of the esophagusGastrointestinal Endoscopy, 2006
- Review article: the pathogenesis and management of eosinophilic oesophagitisAlimentary Pharmacology & Therapeutics, 2006
- Eosinophil cationic protein in atopic eczemaArchives of Dermatological Research, 1991