The Role of Daily Implant-Based Multiparametric Telemonitoring in Patients with a Ventricular Assist Device
Authors:
- Denise GuckelDGDenise Guckel
- Mustapha El HamritiMHMustapha El Hamriti
- Sebastian V. RojasSebastian V. Rojas
- Henrik FoxHFHenrik Fox
- Angelika Costard-JäckleACAngelika Costard-Jäckle
- Jan GummertJGJan Gummert
- Thomas FinkTFThomas Fink
- Vanessa SciaccaVSVanessa Sciacca
- Khuraman IsgandarovaKIKhuraman Isgandarova
- Martin BraunMBMartin Braun
- Moneeb KhalaphMKMoneeb Khalaph
- Guram ImnadzeGIGuram Imnadze
Open Access
Abstract
The telemonitoring of heart failure (HF) patients is becoming increasingly important. This study aimed to evaluate the benefit of telemonitoring in end-stage HF patients with a ventricular-assistance device (VAD). A total of 26 HF-patients (66 ± 11 years, 88% male) on VAD therapy with an implantable cardioverter-defibrillator (ICD) or a cardiac resynchronization defibrillator (CRT-D) including telemonitoring function were enrolled. The long-term follow-up data (4.10 ± 2.58 years) were assessed. All the patients (n = 26, 100%) received daily ICD/CRT-D telemonitoring. In most of the patients (73%, n = 19), the telemedical center had to take action for a mean of three times. An acute alert due to sustained ventricular arrhythmias (VAs) occurred in 12 patients (63%) with 50% of them (n = 6) requiring ICD shock delivery. Eight patients (67%) were hospitalized due to symptomatic VAs. In 11 patients (92%), immediate medication adjustments were recommended. Relevant lead issues were revealed in thirteen patients (50%), with six patients (46%) undergoing consecutive lead revisions. Most of the events (83%) were detected within 24 h. Daily telemonitoring significantly reduced the number of in-hospital device controls by 44% (p < 0.01). The telemonitoring ensured that cardiac arrhythmias and device/lead problems were identified early, allowing pre-emptive and prompt interventions. In addition, the telemonitoring significantly reduced the number of in-hospital device controls in this cohort of HF patients.Keywords
This publication has 22 references indexed in Scilit:
- Implant-based multiparameter telemonitoring of patients with heart failure (IN-TIME): a randomised controlled trialThe Lancet, 2014
- Superiority of automatic remote monitoring compared with in-person evaluation for scheduled ICD follow-up in the TRUST trial - testing execution of the recommendationsEuropean Heart Journal, 2014
- Same-day discovery of implantable cardioverter defibrillator dysfunction in the TRUST remote monitoring trial: influence of contrasting messaging systemsEP Europace, 2012
- Remote Monitoring Reduces Healthcare Use and Improves Quality of Care in Heart Failure Patients With Implantable DefibrillatorsCirculation, 2012
- Risk of Mortality for Ventricular Arrhythmia in Ambulatory LVAD PatientsJournal of Cardiovascular Electrophysiology, 2011
- Cardiac resynchronization therapy and the relationship of percent biventricular pacing to symptoms and survivalHeart Rhythm, 2011
- Long-Term Outcome After ICD and CRT Implantation and Influence of Remote Device Follow-UpCirculation, 2010
- Efficacy and Safety of Automatic Remote Monitoring for Implantable Cardioverter-Defibrillator Follow-UpCirculation, 2010
- Remote monitoring and follow-up of pacemakers and implantable cardioverter defibrillatorsEP Europace, 2009
- Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart FailureThe New England journal of medicine, 2005