The changes of relative position of the thoracic aorta after anterior or posterior instrumentation of type I Lenke curve in adolescent idiopathic thoracic scoliosis
- 1 August 2008
- journal article
- research article
- Published by Springer Nature in European Spine Journal
- Vol. 17 (8) , 1019-1026
Abstract
The risk of impingement of the aorta associated with thoracic vertebral screw or pedicle screw instrumentation in the treatment of thoracic scoliosis has been an important concern. To understand this phenomenon more systematically, the relative position of the aorta with reference to the thoracic vertebrae in right thoracic adolescent idiopathic scoliosis (AIS) following anterior and posterior spinal instrumentation was analyzed in detail quantitatively; 34 patients underwent anterior (n = 14) or posterior (n = 20) spinal instrumentation were recruited in the present study. The relative position of the thoracic aorta, vertebral rotation, apical vertebral translation and thoracic kyphosis were measured from pre- and post-operative CT images from T5 to T12. The aorta was found to shift antero-medially in the anterior instrumentation group but not in the posterior spinal instrumentation group. It is likely that the disc removal, soft tissue release and spontaneous vertebral derotation of the scoliosis could account for the antero-medial shifting of the aorta. By the shifting, the space for contralateral screw penetration was reduced.Keywords
This publication has 35 references indexed in Scilit:
- The anatomical relationship between the aorta and the thoracic vertebral bodies and its importance in the placement of the screw in thoracoscopic correction of ScoliosisEuropean Spine Journal, 2007
- The Position of the Aorta Relative to the Spine Before and After Anterior Instrumentation in Right Thoracic ScoliosisSpine, 2006
- Screw Position After Double-Rod Anterior Spinal Fusion in Idiopathic ScoliosisSpine, 2006
- Anterior dual rod instrumentation in idiopathic thoracic scoliosisEuropean Spine Journal, 2006
- Correction of flexible thoracic scoliosis below 65 degrees—A radiological comparison of anterior versus posterior segmental instrumentation applied to similar curvesEuropean Spine Journal, 2006
- Comparison of anterior and posterior double-rod instrumentation for thoracic idiopathic scoliosis: results of 141 patientsEuropean Spine Journal, 2006
- Change pattern of somatosensory-evoked potentials after occlusion of segmental vessels: possible indicator for spinal cord ischemiaEuropean Spine Journal, 2005
- Anterior Dual Rod Instrumentation in Idiopathic Thoracic ScoliosisSpine, 2005
- A prospective comparison of thoracoscopic vs open anterior instrumentation and spinal fusion for idiopathic thoracic scoliosis in childrenJournal of Pediatric Surgery, 2005
- Scoliosis Correction by Cotrel-Dubousset Instrumentation. The Effect of Derotation and Three Dimensional CorrectionSpine, 1992