Dependence of time of breakdown on electrode temperatures in nitrogen filled diodes
Authors:
- 14 October 1979
- journal article
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 12 (10) , 1699-1702
Abstract
Time delays of electrical breakdown in a gas-filled diode (td) were measured as a function of the time between two successive measurements ( tau ) at cathode temperatures of 300K, 523K and 673K. The diode was filled with nitrogen at 4 mbar with an oxygen impurity of about 10 ppm. It is shown that the breakdown time delays at 673K are one order of magnitude smaller than those at 300K.Keywords
This publication has 2 references indexed in Scilit:
- Combined spatial and temporal studies of ionization growth in nitrogenJournal of Physics D: Applied Physics, 1976
- Time-Lag Analysis of the Townsend Discharge in Argon with Activated Caesium ElectrodesPhysical Review B, 1940