Combination with antimicrobial peptide lyses improves loop-mediated isothermal amplification based method for Chlamydia trachomatis detection directly in urine sample
Open Access
- 13 July 2016
- journal article
- research article
- Published by Springer Nature in BMC Infectious Diseases
- Vol. 16 (1) , 1-8
Abstract
Chlamydia trachomatis is an obligate intracellular human pathogen and is the most common cause of sexually transmitted diseases affecting both men and women. The pathogen can cause prostatitis and epididymitis in men. In women, cervicitis, pelvic inflammatory disease, ectopic pregnancy and acute or chronic pelvic pain are frequent complications. More than half of C. trachomatis-positive patients have minimal or no symptoms, providing an ongoing reservoir for the infection. The lack of sensitive large-scale applicable point- of- care (POC) tests for C. trachomatis detection makes it difficult to diagnose chlamydia infection efficiently in resource-limited environments. A rapid and sensitive assay based on loop-mediated isothermal amplification method (LAMP) was combined with antimicrobial peptide lysis, which is able to detect at least 7 C. trachomatis pathogens per reaction directly from urine samples. Our study comprising 91 first-void urine samples showed that specificity of the assay is 100 % and sensitivity 73 % when using antimicrobial peptide lysis mix. Additionally we demonstrate that our assay does not give any cross-reactivity with 30 pathogen’s DNA potentially present in the urine samples. Furthermore, the assay’s novel approach does not require purification or extraction of DNA from clinical sample prior to amplification, so the need for specialized equipment is eliminated. The whole procedure is significantly less laborious, less time-consuming and consequently less expensive for early detection and identification of infectious disease. C. trachomatis specific LAMP assay is relatively simple to perform and could therefore be applied in numerous POC settings.Keywords
Funding Information
- Estonian Research Council (PUT753)
- Sächsische Aufbaubank (SAB#100144699)
This publication has 42 references indexed in Scilit:
- Blind Evaluation of the Microwave-Accelerated Metal-Enhanced Fluorescence Ultrarapid and Sensitive Chlamydia trachomatis Test by Use of Clinical SamplesJournal of Clinical Microbiology, 2013
- A Multiplexed Microfluidic PCR Assay for Sensitive and Specific Point-of-Care Detection of Chlamydia trachomatisPLOS ONE, 2012
- Point-of-Care Test for Detection of Urogenital Chlamydia in Women Shows Low Sensitivity. A Performance Evaluation Study in Two Clinics in SurinamePLOS ONE, 2012
- Evaluation of the Abbott RealTi m e CT/NG Assay in Comparison to the Roche Cobas Amplicor CT/NG AssayJournal of Clinical Microbiology, 2011
- Clinic-Based Evaluation of a Rapid Point-of-Care Test for Detection of Chlamydia trachomatis in Specimens from Sex Workers in Escuintla, GuatemalaJournal of Clinical Microbiology, 2009
- Evaluation of the Rapid BioStar Optical Immunoassay for Detection of Chlamydia trachomatis in Adolescent WomenJournal of Clinical Microbiology, 2009
- Loop-Mediated Isothermal Amplification Assay for Rapid Detection of Common Strains ofEscherichia coliJournal of Clinical Microbiology, 2008
- Antimicrobial peptides of the Cecropin-family show potent antitumor activity against bladder cancer cellsBMC Urology, 2008
- Global epidemiology of sexually transmitted diseasesAsian Journal of Andrology, 2008
- Clinic-based evaluation of Clearview Chlamydia MF for detection of Chlamydia trachomatis in vaginal and cervical specimens from women at high risk in ChinaSexually Transmitted Infections, 2006