Ineffective Cleaning of Polysulfone Ultrafiltration Membrane Systems and Corrosion by Bisulfite Used as a Sanitizer

Authors:
  • KSKaren E. Smith
    Karen E. Smith
  • RBR.L. Bradley
    R.L. Bradley

Abstract
Bisulfite solution was used to sanitize polysulphone ultrafiltration membranes. The uhrafiltration system consisted of a 380-L jacketed vat with agitator, prefilter, centrifugal pump, and two polysulphone uhrafihration membranes in parallel with valves and pressure gauges before and after the membranes. The system was soiled by recycling 380 L of sweet whey (40°C) for 2.0 h followed by concentrating (by diverting permeate steam to drain) whey for .5 h. The cleaning cycle consisted of acid cleaner (.5 h, 40°C) followed by enzyme cleaner (10.0 h, 40°C) and rinsing (2.0 h, 40°C). A .2% sodium metabisulfite solution was circulated for 5 min and the ultrafiltration unit left idle overnight. Swabs and rinse water samples were taken immediately after soiling, after cleaning, and the next morning to check sanitizing. Samples were plated on plate count agar and potato glucose agar (acidified with tartaric acid to pH 3.5) to determine numbers of bacteria, yeasts, and molds. Effectiveness of bisulfite was pH dependent. At pH 4.7, bisulfite solution was ineffective in controlling microorganisms and at pH 3.5, bisulfite was microstatic. Compared with trials with Antibac B (30 ppm (21), bisulfite (pH 3.5) was similar for controlling bacteria, yeasts, and molds. Extensive corrosion of stainless steel housings was apparent following longterm contact (2 wk) with bisulfite solution. Laboratory trials using stainless steel fittings, plates, and rubber gaskets