An evaluation of the robustness of the Tanaka characterization protocol for reversed‐phase liquid chromatography columns
- 25 October 2005
- journal article
- research article
- Published by Wiley in Journal of Separation Science
- Vol. 28 (16) , 2120-2129
Abstract
The robustness of the popular ‘Tanaka’ LC column characterization protocol has been evaluated by the statistical tools of reduced factorial design, multiple linear regression and principal component analysis. These have shown that in order to obtain reliable and reproducible results, it is especially important to control the methanol content, the temperature and, in the case of the total ion‐exchange capacity test (αB/P pH 7.6), the pH of the mobile phase. In particular, the hydrophobicity tests (kPB and αequation/tex2gif-inf-3.gif) are sensitive to small changes in methanol content. Provided that the operating parameters for the Tanaka column characterization protocol are controlled within the following experimental limits, i. e. methanol content ±0.5% v/v, temperature ±3°C, pH ±0.10 and buffer concentration ±2.0 mM, it is feasible to distinguish between RP materials that possess selectivity differences larger than their batch‐to‐batch reproducibility. These experimental requirements can be easily met by current LC instrumentation. Hence, the validity of the Tanaka testing protocol for characterizing columns has been verified.Keywords
This publication has 43 references indexed in Scilit:
- Chromatographic classification and comparison of commercially available perfluorinated stationary phases for reversed‐phase liquid chromatography using Principal Component AnalysisJournal of Separation Science, 2003
- Characterization of HPLC packingsJournal of Separation Science, 2003
- A new standard reference material for column evaluation in reversed‐phase liquid chromatographyJournal of Separation Science, 2003
- Trends and progress in the characterization of stationary phases for reversed-phase liquid chromatographyTrAC Trends in Analytical Chemistry, 2001
- Repeatability and reproducibility of retention data and band profiles on reversed-phase liquid chromatography columnsJournal of Chromatography A, 2000
- Chromatographic Determination of Metallic Impurities in Reversed-Phase HPLC ColumnsAnalytical Chemistry, 1999
- Comparative study of test methods for reversed-phase columns for high-performance liquid chromatographyJournal of Chromatography A, 1998
- Robustness testing in liquid chromatography and capillary electrophoresisJournal of Pharmaceutical and Biomedical Analysis, 1996
- Ruggedness testing in analytical chemistryTrAC Trends in Analytical Chemistry, 1988
- Statistics for Experimenters: An Introduction to Design, Data Analysis, and Model BuildingJournal of Marketing Research, 1979