Abstract
This paper presents an improved complex-vector dynamic model for a three-phase induction machine (IM) with stator interturn short-circuit fault. The paper proposes an accurate and meaningful approach to the faulty stator leakage inductance and describes a nonlinear phenomenon in the faulty circuit. The asymmetric model is developed in detail and represented in state-space (SS) form with the flux-linkages as the SS variable. Based on the proposed model, steady-state complex-vector, operational, and sequence component equivalent circuits are derived for fault detection and identification purposes. For reasons of verification, the model is simulated in MatLab environment and experimentally corroborated for a 1HP three-phase squirrel-cage IM. The simulations and experiments are compared at no-load and loading condition for both transient and steady-state response. The permanent regime analysis studies the model with respect to the fault severity factor, fault resistance, and load variation. The proposed model shows high correlation with the experimental results.Keywords
Funding Information
- Office of Naval Research
This publication has 24 references indexed in Scilit:
- Dynamic space-vector model of induction machines with stator inter-turn short-circuit fault2015
- Neural network based method for the automatic detection of the stator faults of the induction motor2013
- Wound-Rotor Induction Generator Inter-Turn Short-Circuits Diagnosis Using a New Digital Neural NetworkIEEE Transactions on Industrial Electronics, 2012
- A Detailed Model of Induction Machines With Saturation Extendable for Fault AnalysisIEEE Transactions on Industry Applications, 2004
- A model of asynchronous machines for stator fault detection and isolationIEEE Transactions on Industrial Electronics, 2003
- Transient model for induction machines with stator winding turn faultsIEEE Transactions on Industry Applications, 2002
- Transient analysis of cage induction machines under stator, rotor bar and end ring faultsIEEE Transactions on Energy Conversion, 1995
- Multiple coupled circuit modeling of induction machinesIEEE Transactions on Industry Applications, 1995
- Modeling of saturated AC machines including air gap flux harmonic componentsIEEE Transactions on Industry Applications, 1992