Predictors of fluid responsiveness in critically ill patients mechanically ventilated at low tidal volumes: systematic review and meta-analysis
Open Access
- 8 February 2021
- journal article
- review article
- Published by Elsevier in Annals of Intensive Care
- Vol. 11 (1) , 1-17
Abstract
Introduction: Dynamic predictors of fluid responsiveness have shown good performance in mechanically ventilated patients at tidal volumes (Vt) > 8 mL kg −1 . Nevertheless, most critically ill conditions demand lower Vt. We sought to evaluate the operative performance of several predictors of fluid responsiveness at Vt ≤ 8 mL kg −1 by using meta-regression and subgroup analyses. Methods: A sensitive search was conducted in the Embase and MEDLINE databases. We searched for studies prospectively assessing the operative performance of pulse pressure variation (PPV), stroke volume variation (SVV), end-expiratory occlusion test (EEOT), passive leg raising (PLR), inferior vena cava respiratory variability (Δ-IVC), mini-fluid challenge (m-FC), and tidal volume challenge (VtC), to predict fluid responsiveness in adult patients mechanically ventilated at Vt ≤ 8 ml kg −1 , without respiratory effort and arrhythmias, published between 1999 and 2020. Operative performance was assessed using hierarchical and bivariate analyses, while subgroup analysis was used to evaluate variations in their operative performance and sources of heterogeneity. A sensitivity analysis based on the methodological quality of the studies included (QUADAS-2) was also performed. Results: A total of 33 studies involving 1,352 patients were included for analysis. Areas under the curve (AUC) values for predictors of fluid responsiveness were: for PPV = 0.82, Δ-IVC = 0.86, SVV = 0.90, m-FC = 0.84, PLR = 0.84, EEOT = 0.92, and VtC = 0.92. According to subgroup analyses, variations in methods to measure cardiac output and in turn, to classify patients as responders or non-responders significantly influence the performance of PPV and SVV ( p < 0.05). Operative performance of PPV was also significantly affected by the compliance of the respiratory system ( p = 0.05), while type of patient ( p < 0.01) and thresholds used to determine responsiveness significantly affected the predictability of SVV ( p = 0.05). Similarly, volume of fluids infused to determine variation in cardiac output, significantly affected the performance of SVV ( p = 0.01) and PLR ( p < 0.01). Sensitivity analysis showed no variations in operative performance of PPV ( p = 0.39), SVV ( p = 0.23) and EEOT ( p = 0.15). Conclusion: Most predictors of fluid responsiveness reliably predict the response of cardiac output to volume expansion in adult patients mechanically ventilated at tidal volumes ≤ 8 ml kg −1 . Nevertheless, technical and clinical variables might clearly influence on their operative performanceKeywords
This publication has 68 references indexed in Scilit:
- Multiple gene-to-gene interactions in children with sepsis: a combination of five gene variants predicts outcome of life-threatening sepsisCritical Care, 2014
- QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy StudiesAnnals of Internal Medicine, 2011
- An Increase in Aortic Blood Flow after an Infusion of 100 ml Colloid over 1 Minute Can Predict Fluid ResponsivenessAnesthesiology, 2011
- Respiratory pulse pressure variation fails to predict fluid responsiveness in acute respiratory distress syndromeCritical Care, 2011
- The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate health care interventions: explanation and elaborationJournal of Clinical Epidemiology, 2009
- Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: A systematic review of the literature*Critical Care Medicine, 2009
- Influence of Respiratory Rate on Stroke Volume Variation in Mechanically Ventilated PatientsAnesthesiology, 2009
- Automated pre‐ejection period variation indexed to tidal volume predicts fluid responsiveness after cardiac surgeryActa Anaesthesiologica Scandinavica, 2009
- Prediction of fluid responsiveness in acute respiratory distress syndrome patients ventilated with low tidal volume and high positive end-expiratory pressure*Critical Care Medicine, 2008
- Online Monitoring of Pulse Pressure Variation to Guide Fluid Therapy After Cardiac SurgeryAnesthesia & Analgesia, 2008