A New Echocardiographic Tool for Cardiac Output Evaluation: An Experimental Study
- 1 October 2019
- journal article
- research article
- Published by Wolters Kluwer Health in Shock
- Vol. 52 (4) , 449-455
Abstract
Background: The correlation between cardiac output (CO) evaluated by echocardiography and CO measured by thermodilution (COth) varies according to different studies. A new transthoracic echocardiography (TTE) tool allows automatic calculation of the subaortic velocity time index (VTIauto) and CO (COauto). The main objective was to evaluate the correlation between COth and COauto in an anesthetized, ventilated piglet hemorrhagic shock (HS) model. The secondary objectives were to evaluate the correlation between COth and CO evaluated by manual measurements of VTI, and the preload-dependency of VTIvaresp. Methods: Eighteen piglets were bled until mean arterial pressure reached 40 mm Hg. Controlled hemorrhage was maintained for 30 min before a resuscitation phase. CO was measured by Pulse index Contour Cardiac Output thermodilution methods. At each time of the experiment, three VTI values were measured (min, med, max) and the average value was calculated. COs were calculated by TTE (COmax, COmed, COmin, COave). Results: For the 204 measures attempted, the success rate was 197 (97%) manually and 122 (60%) automatically (P < 0.01). The correlation coefficients (r) between COth and, respectively, COauto, COave, COmax, COmed, and COmin were: 0.83 (95% CI [0.76; 0.88]; P < 0.01), 0.54 (95% CI [0.43; 0.63]; P < 0.01), 0.43 (95% CI [0.31; 0.54]; P < 0.01), 0.58 (95% CI [0.48; 0.67]; P < 0.01), and 0.52 (95% CI [0.41; 0.62]; P < 0.01). Conclusion: In an experimental model of HS, a new ultrasound tool, COauto, seems better correlated with COth than manual echocardiographic measurements.Keywords
This publication has 25 references indexed in Scilit:
- Does the type of fluid affect rapidity of shock reversal in an anaesthetized-piglet model of near-fatal controlled haemorrhage? A randomized studyBritish Journal of Anaesthesia, 2013
- Plethysmographic variation index predicts fluid responsiveness in ventilated patients in the early phase of septic shock in the emergency department: A pilot studyJournal of Critical Care, 2013
- Predicting fluid responsiveness with transthoracic echocardiography is not yet evidence basedActa Anaesthesiologica Scandinavica, 2012
- Multicenter Study Verifying a Method of Noninvasive Continuous Cardiac Output Measurement Using Pulse Wave Transit TimeAnesthesia & Analgesia, 2012
- Assessing left ventricular systolic function in shock: evaluation of echocardiographic parameters in intensive careCritical Care, 2011
- Clinical review: Update on hemodynamic monitoring - a consensus of 16Critical Care, 2011
- Doppler Echocardiography in Advanced Systolic Heart FailureCirculation: Heart Failure, 2010
- The Influence of Tidal Volume on the Dynamic Variables of Fluid Responsiveness in Critically Ill PatientsAnesthesia & Analgesia, 2006
- Relation between Respiratory Changes in Arterial Pulse Pressure and Fluid Responsiveness in Septic Patients with Acute Circulatory FailureAmerican Journal of Respiratory and Critical Care Medicine, 2000
- Cardiac output can be reliably measured noninvasively after coronary artery bypass grafting operationCritical Care Medicine, 1999