Design and Testing of an Ultralow Q CBPM
- 8 March 2022
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 69 (7) , 1702-1711
Abstract
High repetition rates are considered essential to meet the anticipated new demands of the free-electron laser (FEL) facility. To offer precise beam handling for high-repetition-rate FEL facilities operating in a multi bunch mode, an ultralow quality factor (Q) cavity beam position monitor (CBPM) is studied to distinguish nanosecond spaced electron bunches, enabling the independent position measurement of each bunch and reducing the contamination between bunch signals. The low-Q CBPM consists of two cavities: a reference cavity and a position cavity. The reference cavity is mainly used for bunch charge normalization, and the position cavity can measure the beam position vertically and horizontally. This paper studies the method to attain a low loaded quality factor for the CBPM and presents the design and preliminary test results. The test results show that the loaded quality factors of the reference cavity and the position cavity can both reach 13, which enables bunch position monitoring for those high repetition rate FEL facilities.Keywords
Funding Information
- National Key Research and Development Project of China (2016YFA0401903)
- National Natural Science Foundation of China (12035012)
This publication has 9 references indexed in Scilit:
- A single stage EEHG at SXFEL for narrow-bandwidth soft X-ray generationScience Bulletin, 2016
- PAL-XFEL cavity beam position monitor pick-up design and beam testNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2016
- Design and performance of a high resolution, low latency stripline beam position monitor systemPhysical Review Special Topics - Accelerators and Beams, 2015
- Design and test of SX-FEL cavity BPMChinese Physics C, 2013
- Nyquist-Rate Data Conversion2009
- Development of a high-resolution cavity-beam position monitorPhysical Review Special Topics - Accelerators and Beams, 2008
- Design and performance of the LCLS cavity BPM system2007
- Experimental results from a microwave cavity beam position monitor2003
- Cavity beam position monitorsAIP Conference Proceedings, 1998