Wearable Piezoelectric Airflow Transducers for Human Respiratory and Metabolic Monitoring
Open Access
- 22 July 2022
- journal article
- research article
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 7 (8) , 2281-2292
Abstract
Despite the importance of respiration and metabolism measurement in daily life, they are not widely available to ordinary people because of sophisticated and expensive equipment. Here, we first report a straightforward and economical approach to monitoring respiratory function and metabolic rate using a wearable piezoelectric airflow transducer (WPAT). A self-shielded bend sensor is designed by sticking two uniaxially drawn piezoelectric poly l-lactic acid films with different cutting angles, and then the bend sensor is mounted on one end of a plastic tube to engineer the WPAT. The airflow sensing principle of the WPAT is theoretically determined through finite element simulation, and the WPAT is calibrated with a pulse calibration method. We prove that the WPAT has similar accuracy (correlation coefficient >0.99) to a pneumotachometer in respiratory flow and lung volume assessment. We demonstrate metabolism measurement using the WPAT and the relationship between minute volume and metabolic rates via human wear trials. The mean difference of measured metabolic rates between the WPAT and a Biopac indirect calorimeter is 0.015 kcal/min, which shows comparable performance. Significantly, unlike the Biopac indirect calorimeter with an airflow sensor, an oxygen gas sensor, and a carbon dioxide gas sensor, we merely use the simple-structured WPAT to measure metabolism. Thus, we expect the WPAT technology to provide a precise, convenient, and cost-effective respiratory and metabolic monitoring solution for next-generation medical home care applications and wearable healthcare systems.Keywords
Funding Information
- University of Manchester (AA14512)
- Horizon 2020 Framework Programme (644268)
This publication has 35 references indexed in Scilit:
- Film Sensor Device Fabricated by a Piezoelectric Poly(L-lactic acid) FilmJapanese Journal of Applied Physics, 2012
- Do Handheld Calorimeters Have a Role in Assessment of Nutrition Needs in Hospitalized Patients?Nutrition in Clinical Practice, 2011
- Validation of the BIOPAC indirect calorimeter for determining resting energy expenditure in healthy free-living older peopleNutrition Research, 2009
- Doubly labelled water for the measurement of total energy expenditure in man – progress and applications in the last decadeNutrition Bulletin, 2008
- Validation of the VO2000 calorimeter for measuring resting metabolic rateClinical Nutrition, 2006
- Standardisation of spirometryEuropean Respiratory Journal, 2005
- Branched equation modeling of simultaneous accelerometry and heart rate monitoring improves estimate of directly measured physical activity energy expenditureJournal of Applied Physiology, 2004
- Measuring human energy expenditure: What have we learned from the flex‐heart rate method?American Journal of Human Biology, 2003
- Methodological Considerations for Researchers and Practitioners Using Pedometers to Measure Physical (Ambulatory) ActivityResearch Quarterly for Exercise and Sport, 2001
- Acceptable levels for the breathing resistance of respiratory apparatus: results for men over the age of 45.Occupational and Environmental Medicine, 1977