Design of a Micro-Plant Factory Using a Validated CFD Model
Open Access
- 5 December 2024
- journal article
- research article
- Published by MDPI AG in Agriculture
- Vol. 14 (12) , 2227
Abstract
The uniformity of the cultivation environment in a micro-plant factory plays a critical role in ensuring the consistent growth of seedlings, and an optimal airflow pattern is the key to maintaining environmental uniformity. This study applied computational fluid dynamics (CFD) modeling to compare the effects of six different ventilation modes on the microclimate within the cultivation space. In cases 1 and 2, the inlet was positioned at the top, while the outlets were located at both the bottom and the top of the side walls. For cases 3 to 6, a side-inlet and side-outlet ventilation system was employed across the three cultivation layers. Case 4 maintained consistent inlet and outlet airflow speeds, whereas cases 3, 5, and 6 featured airflow settings that either increased or decreased progressively from the top layer to the bottom. Notably, case 6 was characterized by a more compact arrangement of cultivation racks within the space, which were positioned closer to the outlet than in the other cases. In case 1, the air inlets were positioned at the top, while the outlets were located on both side walls at the lower layer of cultivation. In contrast, case 6 used a side-inlet and side-outlet ventilation strategy, in which the airflow speed of the inlets decreases progressively from the top to the bottom of the cultivation layers. Additionally, the cultivation racks in case 6 were arranged more compactly and positioned closer to the outlet of the cultivation space. The relative standard deviation (RSD) was used to evaluate the uniformity of the airflow velocity (m/s), temperature (K), and relative humidity (%) within the crop-growing area. The results indicated that, among all the scenarios, case 6 demonstrated the lowest RSD values for the airflow velocity, temperature, and relative humidity, with reductions of 18.34%, 0.12%, and 2.05%, respectively, compared to the control group (case 1). Based on the ventilation design of case 6, a micro-plant factory was developed featuring a bidirectional flow fan, air conditioning, and PWM fans for the coordinated control of air circulation within the seedling cultivation space, along with adjustable cultivation layer heights and shelf spacing. The accuracy of the CFD model for the micro-plant factory was validated with normalized root mean square error (NMSE) for cultivation layer heights of 250 mm, 300 mm, and 350 mm. The NMSE values comparing the simulated and measured results for the airflow velocity, temperature, and relative humidity were found to be 0.032, 0.0020, and 0.0022; 0.031, 0.0021, and 0.0018; and 0.046, 0.0021, and 0.0021, respectively. These findings indicate that the established CFD model can reliably predict the microenvironment within the micro-plant factory.Keywords
Funding Information
- National Natural Science Foundation of China (31901455, 2023-02-08-00-12-F04592, 23KJB210004, PAPD-2023-87, BK20240880)
- Research and Development of Key Intelligent Technologies for Fully Automated Lettuce Transplanting Equipment (31901455, 2023-02-08-00-12-F04592, 23KJB210004, PAPD-2023-87, BK20240880)
- General Program of Basic Science Research in Higher Education Institutions of Jiangsu Province (31901455, 2023-02-08-00-12-F04592, 23KJB210004, PAPD-2023-87, BK20240880)
- Priority Academic Program Development of Jiangsu Higher Education Institutions (31901455, 2023-02-08-00-12-F04592, 23KJB210004, PAPD-2023-87, BK20240880)
- Natural Science Foundation of Jiangsu Province for Youth (31901455, 2023-02-08-00-12-F04592, 23KJB210004, PAPD-2023-87, BK20240880)
This publication has 47 references indexed in Scilit:
- Protein plant factories: production and resource use efficiency of soybean proteins in vertical farmingJournal of the Science of Food and Agriculture, 2024
- Thermo-fluid dynamic analysis of the air flow inside an indoor vertical farming systemApplied Thermal Engineering, 2023
- Validation of an air temperature gradient using computational fluid dynamics in a semi-open type greenhouse and determination of kimchi cabbage physiological responses to temperature differencesHorticulture, Environment, and Biotechnology, 2021
- Evaluation of the light profile and carbon assimilation of tomato plants in greenhouses with respect to film diffuseness and regional solar radiation using ray-tracing simulationAgricultural and Forest Meteorology, 2021
- A CFD analysis on improving lettuce canopy airflow distribution in a plant factory considering the crop resistance and LEDs heat dissipationBiosystems Engineering, 2020
- Plant factories versus greenhouses: Comparison of resource use efficiencyAgricultural Systems, 2018
- A CFD study on improving air flow uniformity in indoor plant factory systemBiosystems Engineering, 2016
- Airflow and microclimate patterns in a one-hectare Canary type greenhouse: An experimental and CFD assisted studyAgricultural and Forest Meteorology, 2009
- 3-D CFD analysis of relative humidity distribution in greenhouse with a fog cooling system and refrigerative dehumidifiersBiosystems Engineering, 2008
- A new k-ϵ eddy viscosity model for high reynolds number turbulent flowsComputers & Fluids, 1995