Influence of centrifuge brake on residual platelet count and routine coagulation tests in citrated plasma
Authors:
- 1 April 2014
- journal article
- technical report
- Published by Wolters Kluwer Health in Blood Coagulation & Fibrinolysis
- Vol. 25 (3) , 292-295
Abstract
Sample centrifugation is an essential step in the coagulation laboratory, as clotting tests are typically performed on citrated platelet (PLT) poor plasma (PPP). Nevertheless, no clear indication has been provided as to whether centrifugation of specimens should be performed with the centrifuge brake set to on or off. Fifty consecutive sodium citrate anticoagulated samples were collected and divided into two aliquots. The former was centrifuged as for Clinical Laboratory Standards Institute (CLSI) guidelines with the centrifuge brake set to on, whereas the latter was centrifuged again as for CLSI guidelines, but with the brake set to off. In the PPP of all samples, a PLT count was performed, followed by the analysis of activated partial thromboplastin time (APTT), prothrombin time (PT) and fibrinogen (FBG). The PLT count after samples centrifugation was substantially reduced, either with centrifuge brake set to on or off (5 ± 1 versus 3 ± 1 × 109/l; P = 0.009). The frequency of samples exceeding a PLT count less than 10 × 109/l was nearly double in samples centrifuged with the brake on than in those with the brake off (14 versus 8%; P < 0.01). Although no significant difference was found for APTT values, PT was slightly prolonged using the centrifuge brake set to on (mean bias 0.2 s; P < 0.001). FBG values were also significantly higher using the centrifuge brake set to on (mean bias 0.29 g/l; P < 0.001). The results of this study indicate that sample centrifugation for routine coagulation testing should be preferably performed with the centrifuge brake set to off for providing a better quality specimen.Keywords
This publication has 9 references indexed in Scilit:
- Quality Standards for Sample Processing, Transportation, and Storage in Hemostasis TestingSeminars in Thrombosis and Hemostasis, 2012
- Quality Standards for Sample Collection in Coagulation TestingSeminars in Thrombosis and Hemostasis, 2012
- Initial performance evaluation of the UniCel® DxH 800 Coulter® cellular analysis systemInternational Journal of Laboratory Hematology, 2011
- Dishomogeneous separation of citrated plasma in primary collection tubes for routine coagulation testingBlood Coagulation & Fibrinolysis, 2008
- Influence of the centrifuge time of primary plasma tubes on routine coagulation testingBlood Coagulation & Fibrinolysis, 2007
- Preanalytical variability: the dark side of the moon in laboratory testingClinical Chemistry and Laboratory Medicine (CCLM), 2006
- Back to the future: testing in disseminated intravascular coagulationBlood Coagulation & Fibrinolysis, 2005
- Fibrinogen and fibrin structure and functionsJournal of Thrombosis and Haemostasis, 2005
- Current databases on biological variation: pros, cons and progressScandinavian Journal of Clinical and Laboratory Investigation, 1999