A new voltammetric sensor according to graphene quantum dots/ionic liquid modified carbon paste electrode for amaranth sensitive determination
- 19 February 2020
- journal article
- research article
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 102 (3) , 789-803
Abstract
The voltammetric determination of amaranth is performed on the carbon paste electrode (CPE) surface that is enhanced using graphene quantum dots (GQD). The structure of ionic liquid (IL) may be used as an electrode modifier. Transmission electron microscopy (TEM) and Fourier transform infrared (FT-IR) analysis are used for characterising mentioned materials. The amaranth oxidation is performed by, chronoamperometry, and cyclic voltammetry (CV) as well as differential pulse voltammetry (DPV). It is done in a solution of blank phosphate buffer. Our suggested approach demonstrated proper linearity more than the range from 0.1 to 400.0 µM. In addition, the detection limit was lower 0.03 µM under the optimal conditions. The modified electrode shows appropriate selectivity for amaranth. In real samples, the rendered approach is used to amaranth determination, successfully.Keywords
This publication has 84 references indexed in Scilit:
- Electrochemical Analysis of Some Toxic Metals by Ion–Selective ElectrodesCritical Reviews in Analytical Chemistry, 2011
- Electrochemical Detection of Amaranth in Food Based on the Enhancement Effect of Carbon Nanotube FilmJournal of Agricultural and Food Chemistry, 2010
- Second order advantage in the determination of amaranth, sunset yellow FCF and tartrazine by UV–vis and multivariate curve resolution-alternating least squaresAnalytica Chimica Acta, 2009
- Determination of carbohydrates by capillary zone electrophoresis with amperometric detection at a nano-nickel oxide modified carbon paste electrodeFood Chemistry, 2008
- Voltammetric Determination of Uric Acid at a Fullerene‐C60‐Modified Glassy Carbon ElectrodeElectroanalysis, 2005
- Cadmium(II)-selective sensors based on dibenzo-24-crown-8 in PVC matrixAnalytica Chimica Acta, 1999
- PVC-Based 2,2,2-Cryptand Sensor for Zinc IonsAnalytical Chemistry, 1996
- Neutral carrier and organic resin based membranes as sensors for uranyl ionsAnalytical Proceedings including Analytical Communications, 1995
- Copper(II)-selective electrodes based on macrocyclic compoundsAnalytical Proceedings including Analytical Communications, 1995
- Caesium PVC–crown (dibenzo-24-crown-8) based membrane sensorAnalytical Proceedings including Analytical Communications, 1995