Determination of UV filters in river water samples by in‐line SPE‐CE‐MS
- 6 November 2012
- journal article
- research article
- Published by Wiley in Electrophoresis
- Vol. 34 (3) , 374-382
Abstract
The use of SPE coupled in‐line to CE using electrospray MS detection (in‐line SPE‐CE‐ESI‐MS) was investigated for the preconcentration and separation of four UV filters: benzophenone‐3, 2,2‐dihydroxy‐4‐methoxybenzophenone, 2,4‐dihydroxybenzophenone and 2‐phenylbenzimidazole‐5‐sulphonic acid. First, a CE‐ESI‐MS method was developed and validated using standard samples, obtaining LODs between 0.06 μg/mL and 0.40 μg/mL. For the in‐line SPE‐CE‐ESI‐MS method, three different sorbents were evaluated and compared: Oasis HLB, Oasis MCX, and Oasis MAX. For each sorbent, the main parameters affecting the preconcentration performance, such as sample pH, volume, and composition of the elution plug, and sample injection time were studied. The Oasis MCX sorbent showed the best performance and was used to validate the in‐line SPE‐CE‐ESI‐MS methodology. The LODs reached for standard samples were in the range between 0.01 and 0.05 ng/mL with good reproducibility and the developed strategy provided sensitivity enhancement factors between 3400‐fold and 34 000‐fold. The applicability of the developed methodology was demonstrated by the analysis of UV filters in river water samples.Keywords
This publication has 51 references indexed in Scilit:
- Developments in coupled solid‐phase extraction–capillary electrophoresis 2009–2011Electrophoresis, 2011
- Recent advances in CE‐MS: Synergy of wet chemistry and instrumentation innovationsElectrophoresis, 2010
- Widespread occurrence of estrogenic UV-filters in aquatic ecosystems in SwitzerlandEnvironmental Pollution, 2010
- Solid-phase extraction followed by liquid chromatography–tandem mass spectrometry for the determination of hydroxylated benzophenone UV absorbers in environmental water samplesAnalytica Chimica Acta, 2009
- Organic UV filters and their photodegradates, metabolites and disinfection by-products in the aquatic environmentTrAC Trends in Analytical Chemistry, 2008
- Cloud point extraction combined with micellar electrokinetic capillary chromatography determination of benzophenones in cosmetic matrixElectrophoresis, 2008
- Development of a frit-free SPE-based in-column preconcentration system for capillary electrophoresisJournal of Pharmaceutical and Biomedical Analysis, 2007
- Improving the sensitivity of the determination of ceftiofur by capillary electrophoresis in environmental water samples: In-line solid phase extraction and sample stacking techniquesAnalytica Chimica Acta, 2007
- Enantioselective separation of the sunscreen agent 3-(4-methylbenzylidene)-camphor by electrokinetic chromatography: Quantitative analysis in cosmetic formulationsElectrophoresis, 2005
- Comparison of microemulsion electrokinetic chromatography and micellar electrokinetic chromatography as methods for the analysis of ten benzophenonesElectrophoresis, 2005