Knee flexion influences periprosthetic BMD measurement in the tibia
Open Access
- 30 June 2010
- journal article
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 81 (4) , 463-470
Abstract
The quality and quantity of bone is important for the success of joint prostheses and may be monitored by dual energy X-ray absorptiometry (DXA). Available protocols suggest that the knee should be positioned in full extension. This is not possible for most patients in the first days after surgery; however, deficits in extension normalize with rehabilitation. Individual knee flexion between the baseline and follow-up investigations may therefore be different. We investigated the sensitivity of bone mineral density (BMD) measurements to knee flexion in a phantom study and in patients. We suggest a protocol for clinical use. 2 phantom tibial bones with tibia components were secured in a clamp and BMD measurements were repeated 5 times at every 5 degrees change in flexion from 0 degrees to 20 degrees. For clinical use, a soft foam positioner was produced, in which the lower leg could be placed in neutral rotation and with the knee in approximately 25 degrees of flexion. The clinical repeatability was tested with double examinations in 38 patients. We investigated 3 regions of interest (ROIs) below the tibial plateau. In the phantom study, just 5 degrees of flexion was found to change the measured mean BMD. The reproducibility of clinical measurements (coefficient of variation) in the 3 ROIs assessed ranged from 1.8% to 3.7% for the anteroposterior scans, and from 3.4% to 6.2% for the lateral scans. Knee flexion does affect the measured periprosthetic tibial BMD, and knee flexion should be the same at all clinical follow-ups. The protocol and soft foam positioner that we suggest permit precise and reliable assessment of BMD in the proximal tibia and they can be used in clinical work.Keywords
This publication has 35 references indexed in Scilit:
- Five-year DEXA study of 88 hips with cemented femoral stemInternational Orthopaedics, 2008
- Fixation and Bone Remodeling Around a Low Stiffness Stem in Revision SurgeryClinical Orthopaedics and Related Research, 2008
- Influence of the tibial stem design on bone density after cemented total knee arthroplasty: a prospective seven-year follow-up studyInternational Orthopaedics, 2006
- Peri-prosthetic bone mineral density after total knee arthroplastyThe Journal of Bone and Joint Surgery. British volume, 2006
- Guidelines for standardization of radiostereometry (RSA) of implantsActa Orthopaedica, 2005
- Periprosthetic tibial bone mineral density changes after total knee arthroplastyOne-year follow-up study of 69 patientsActa Orthopaedica, 2004
- Changes in bone mineral density at the proximal tibia after total knee arthroplasty: A 2‐year follow‐up of 28 knees using dual energy x‐ray absorptiometryJournal of Orthopaedic Research, 2000
- Changes in bone mineral density of the distal femur following uncemented total knee arthroplastyThe Journal of Arthroplasty, 1995
- Mechanisms of Failure of the Femoral and Tibial Components in Total Knee ArthroplastyClinical Orthopaedics and Related Research, 1989
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986