Low Activation Fusion Rationale
Authors:
- 1 November 1983
- journal article
- research article
- Published by Taylor & Francis in Nuclear Technology - Fusion
- Vol. 4 (3) , 528-544
Abstract
The potential problems of radioactivation in the materials surrounding a neutron-producing fusion plasma were identified over 8 yr ago. At the same time, the use of low activation materials such as graphite, silicon carbide (SiC), and aluminum alloys was proposed for the structural material in fusion power reactors as a way to greatly reduce the major problems of radioactivity resulting from the more conventional stainless steel materials. A brief review of the current status of the reasons for low activation fusion is presented. Design studies with the low activation materials are not covered here. The consequences of low activation fusion are compared with stainless steel fusion structures and it is found that the radioactivity after reactor shutdown, as measured in curies, may be reduced by a factor of 1 000 00O. Even then, this limit is determined by impurities in the materials rather than the low activation materials themselves. Problems from decay heat with potential meltdown are reduced for...Keywords
This publication has 3 references indexed in Scilit:
- Flexural strength of proof-tested and neutron-irradiated silicon carbideJournal of Nuclear Materials, 1982
- Contribution of Activation Products to Fusion Accident Risk: Part I. A Preliminary InvestigationNuclear Technology - Fusion, 1981
- Low activation materials assessment for fusion reactors1977