Opening of Native Aortic Valve Accomplished After Left Ventricular Assist Device Implantation in Patients With Insufficient Preoperative Beta-Blocker Treatment
Open Access
- 1 January 2015
- journal article
- Published by International Heart Journal (Japanese Heart Journal) in International Heart Journal
- Vol. 56 (3) , 303-308
Abstract
Although we recently demonstrated that opening of a native aortic valve (AV) after left ventricular assist device (LVAD) implantation is a sufficient condition to prevent development of aortic insufficiency (AI), its preoperative predictors remain unknown. Data were obtained from 58 patients who had been treated with continuous flow LVAD for ≥ 6 months at our institute between 2006 and 2014. Opening of native AV was accomplished in 21 patients (36%) at postoperative 6 months. Uni/Multivariate logistic regression analyses demonstrated that a preoperative lower cumulative dose of β-blocker was the only independent predictor for postoperative opening of native AV (P = 0.020, OR 0.905) at the cutoff level of 4.5g (equivalent dose of carvedilol), calculated by an ROC analysis. Prevalence of native AV opening was increased gradually along with improvement of LV ejection fraction only in patients with preoperative insufficient β-blocker treatment during postoperative 6 months (P < 0.05 for both). Patients with opening of native AV had higher exercise capacity and a lower re-admission rate than those with closed native AV during 2-year LVAD support (5% versus 44%, P < 0.05). Opening of native AV during LVAD support is profoundly associated with LV reverse remodeling especially in patients with insufficient preoperative β-blocker exposure probably due to their better responsiveness to combination therapy with β-blocker and LVAD. Patients who accomplished native AV opening can enjoy better exercise performance and avoid re-admission due to cardiovascular events.Keywords
This publication has 20 references indexed in Scilit:
- Prevalence, Significance, and Management of Aortic Insufficiency in Continuous Flow Left Ventricular Assist Device RecipientsCirculation: Heart Failure, 2014
- De Novo Aortic Insufficiency During Long-Term Support on a Left Ventricular Assist DeviceASAIO Journal, 2014
- Aortic Insufficiency in Patients With Sustained Left Ventricular Systolic Dysfunction After Axial Flow Assist Device ImplantationCirculation Journal, 2014
- Management of Aortic Insufficiency in the Continuous Flow Left Ventricular Assist Device PopulationCurrent Heart Failure Reports, 2013
- Efficacy and safety of bisoprolol fumarate compared with carvedilol in Japanese patients with chronic heart failure: results of the randomized, controlled, double-blind, Multistep Administration of bisoprolol IN Chronic Heart Failure II (MAIN-CHF II) studyHeart and Vessels, 2013
- The Development of Aortic Insufficiency in Continuous-Flow Left Ventricular Assist Device–Supported PatientsThe Annals of Thoracic Surgery, 2013
- Late Aortic Insufficiency Related to Poor Prognosis During Left Ventricular Assist Device SupportThe Annals of Thoracic Surgery, 2011
- Less Frequent Opening of the Aortic Valve and a Continuous Flow Pump Are Risk Factors for Postoperative Onset of Aortic Insufficiency in Patients With a Left Ventricular Assist DeviceCirculation Journal, 2011
- Prevalence of de novo aortic insufficiency during long-term support with left ventricular assist devicesThe Journal of Heart and Lung Transplantation, 2010
- Comparison of Candesartan, Enalapril, and Their Combination in Congestive Heart FailureCirculation, 1999