Quality evaluation of no‐reference MR images using multidirectional filters and image statistics
Authors:
- Jinseong JangJJJinseong Jang
- Dosik HwangDHDosik Hwang
- For The Alzheimer'S Disease Neuroimaging InitiativeFIFor The Alzheimer'S Disease Neuroimaging Initiative
- 30 January 2018
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 80 (3) , 914-924
Abstract
Purpose: This study aimed to develop a fully automatic, no‐reference image‐quality assessment (IQA) method for MR images.Methods: New quality‐aware features were obtained by applying multidirectional filters to MR images and examining the feature statistics. A histogram of these features was then fitted to a generalized Gaussian distribution function for which the shape parameters yielded different values depending on the type of distortion in the MR image. Standard feature statistics were established through a training process based on high‐quality MR images without distortion. Subsequently, the feature statistics of a test MR image were calculated and compared with the standards. The quality score was calculated as the difference between the shape parameters of the test image and the undistorted standard images.Results: The proposed IQA method showed a >0.99 correlation with the conventional full‐reference assessment methods; accordingly, this proposed method yielded the best performance among no‐reference IQA methods for images containing six types of synthetic, MR‐specific distortions. In addition, for authentically distorted images, the proposed method yielded the highest correlation with subjective assessments by human observers, thus demonstrating its superior performance over other no‐reference IQAs.Conclusion: Our proposed IQA was designed to consider MR‐specific features and outperformed other no‐reference IQAs designed mainly for photographic images. Magn Reson Med 80:914–924, 2018. © 2018 International Society for Magnetic Resonance in Medicine.Keywords
Funding Information
- National Research Foundation of Korea
This publication has 47 references indexed in Scilit:
- Subjective evaluation of stereoscopic image qualitySignal Processing: Image Communication, 2013
- Synthetic Mri of the Brain in a Clinical SettingActa Radiologica, 2012
- Fast $\ell_1$-SPIRiT Compressed Sensing Parallel Imaging MRI: Scalable Parallel Implementation and Clinically Feasible RuntimeIEEE Transactions on Medical Imaging, 2012
- Low-dose CT reconstruction via edge-preserving total variation regularizationPhysics in Medicine & Biology, 2011
- Impact of scanner hardware and imaging protocol on image quality and compartment volume precision in the ADNI cohortNeuroImage, 2010
- No-reference image quality assessment in contourlet domainNeurocomputing, 2010
- Automatic quality assessment in structural brain magnetic resonance imagingMagnetic Resonance in Medicine, 2009
- Scope of validity of PSNR in image/video quality assessmentElectronics Letters, 2008
- The Alzheimer's disease neuroimaging initiative (ADNI): MRI methodsJournal of Magnetic Resonance Imaging, 2008
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002