Measurements of water contact angle on FR4 and polyimide substrates relating electrochemical migration
- 1 May 2013
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21612528,p. 157-160
Abstract
Contact angle measurements of water droplets were carried out on fiberglass epoxy resin and polyimide substrates related to water condensation effect as an antecedent process of electrochemical migration. It was shown in our previous paper that water condensation intensity depends mainly on the surface roughness (which determines capillary condensation) and on the heat diffusivity of the substrate material as well. However, not only water condensation intensity has a high impact on electrochemical migration but also the water wettability of the surface. The wettability of the different substrates was estimated by the contact angle calculation using the drop shape method. The results correspond to the surface roughness and heat diffusivity differences of the substrates, thus the time to failure values.Keywords
This publication has 3 references indexed in Scilit:
- Effect of water condensation on electrochemical migration in case of FR4 and polyimide substratesJournal of Materials Science: Materials in Electronics, 2013
- Comparing migratory resistive short formation abilities of conductor systems applied in advanced interconnection systemsMicroelectronics Reliability, 2001
- New types of reliability problems in porous ceramic based microdevicesMaterials Chemistry and Physics, 1996