Multi-Sensor Fusion Approach for Cuff-Less Blood Pressure Measurement
Authors:
- Fen MiaoFMFen Miao
- Zeng-Ding LiuZLZeng-Ding Liu
- Ji-Kui LiuJLJi-Kui Liu
- Bo WenBWBo Wen
- Qing-Yun HeQHQing-Yun He
- Ye LiYLYe Li
- 15 March 2019
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 24 (1) , 79-91
Abstract
Ambulatory blood pressure (BP) provides valuable information for cardiovascular risk assessment. The present cuff-based devices are intrusive for long-term BP monitoring, whereas cuff-less BP measurement methods based on pulse transit time or multi-parameter are inferior in robustness and reliability by using electrocardiogram (ECG) and photoplethysmogram signals. This study examined a multi-sensor fusion-based platform and algorithm for systolic BP (SBP), mean arterial pressure (MAP), and diastolic BP (DBP) estimation. The proposed multi-sensor platform was comprised of one ECG sensor and two pulse pressure wave sensors for simultaneous signal collection. After extracting 35 features from the collected signals, a weakly supervised feature selection method was proposed for dimension reduction because the reference oscillometric technique-based BP are intermittent and can be redeemed as coarse-grained labels. BP models were then established using a multi-instance regression algorithm. A total of 85 participants including 17 hypertensive and 12 hypotensive patients were enrolled. Experimental results showed that the proposed approach exhibited good accuracy for diverse population with an estimation error of 1.62 ± 7.76 mmHg for SBP, 1.53 ± 6.03 mmHg for MAP, and 1.49 ± 5.52 for DBP, which complied with the association for the advancement of medical instrumentation standards in BP estimation. Moreover, the estimation accuracy is with random daily fluctuations rather than long-term degradation through a maximum two-month follow-up period indicated good robustness performance. These results suggest that the proposed approach is with high reliability and robustness and thus provides a novel insight for cuff-less BP measurement.Keywords
Funding Information
- National Natural Science Foundation of China (61771465)
- Shenzhen Science and Technology Projects (JCYJ20170413161515911, JCYJ20180703145202065)
- Science and Technology Planning Project of Guangdong Province (2017B030308007)
This publication has 46 references indexed in Scilit:
- Pulse wave analysis as an experimental tool to clinical application: Past and present (Review)Acta Physiologica Hungarica, 2011
- Pulse Wave Analysis2011
- Predicting Arterial Stiffness from radial Pulse Waveform using support vector machinesProcedia Engineering, 2010
- Photoplethysmography and its application in clinical physiological measurementPhysiological Measurement, 2007
- Oscillometric blood pressure measurement used for calibration of the arterial tonometry method contributes significantly to errorEuropean Journal of Anaesthesiology, 2006
- Pulse transit time measured from the ECG: an unreliable marker of beat-to-beat blood pressureJournal of Applied Physiology, 2006
- Arterial stiffness assessed by pulse wave analysis in essential hypertension: relation to 24-h blood pressure profileInternational Journal of Cardiology, 2005
- Pulse wave analysisBritish Journal of Clinical Pharmacology, 2001
- The British Hypertension Society protocol for the evaluation of automated and semi-automated blood pressure measuring devices with special reference to ambulatory systemsJournal Of Hypertension, 1990
- Measurements of Young's modulus of elasticity of the canine aorta with ultrasoundUltrasonic Imaging, 1979