Field and numerical studies on geofoam-infilled dual barriers to screen ground vibrations
- 9 December 2025
- journal article
- Published by Emerald Publishing in Geosynthetics International
- p. 1-20
Abstract
The unwanted vibrations resulting from man-made activities are very common and can cause damage to the surrounding buildings. Previous studies have suggested single barriers for vibration isolation that require unrealistic depth requirements. To effectively control the vibration-related hazards, a geotechnical seismic isolation strategy of dual shallow barriers has been explored in the present work. Geofoam has been used as a filling material in the barriers. Extensive field studies and numerical simulations have been performed to isolate the continuous harmonic vibrations. The Lazan-type mechanical oscillator has been utilized to generate continuous harmonic vibrations of frequencies ranging from 20 to 45 Hz. A comprehensive numerical investigation has been conducted to screen continuous harmonic vibrations. The barriers were found to eliminate vibrations of higher frequency more effectively compared to low-frequency excitations. The isolation efficiency of EPS15-infilled dual barriers of a normalized depth of 0.31 was noticed to be 45% higher than that of the EPS15-infilled single barrier of a similar depth (where EPS is expanded polystyrene). Furthermore, an optimum depth of 0.5 LR for EPS15-infilled dual barriers was noticed to be sufficient to reach the vibration-limiting criteria of isolation efficiency equal to or greater than 75% (where LR is Rayleigh wavelength).Keywords
This publication has 37 references indexed in Scilit:
- Dynamic compaction-induced ground vibration screening using dual open and geofoam-infilled barriers in layered soil media: physical field experiments and numerical simulationsActa Geotechnica, 2025
- Geosynthetic-Based Barrier System for Mitigating Ground VibrationsIndian Geotechnical Journal, 2025
- Barrier Systems to Protect Critical Transportation Infrastructure from Impact-Induced Ground Vibrations2024
- Performance Evaluation of Single and Multiple Trenches in Screening Ground Vibrations2023
- Effect of Influencing Parameters on the Vibration Isolation Efficacy of Geocell Reinforced Soil BedsInternational Journal of Geosynthetics and Ground Engineering, 2020
- Application of expanded polystyrene (EPS) in buildings and constructions: A reviewJournal of Applied Polymer Science, 2019
- Non Destructive Testing for EPS Geofoam Quality Assurance2018
- Analysis and design of open trench barriers in screening steady-state surface vibrationsEarthquake Engineering and Engineering Vibration, 2014
- Base Isolation of Buildings for Control of Ground‐Borne Vibration2007
- Analysis, testing, and implementation of seismic isolation of buildings in ChileEarthquake Engineering & Structural Dynamics, 2004