Purpose: To investigate the relationship between intraocular pressure (IOP) and big bubble (BB) formation in a model of deep anterior lamellar keratoplasty (DALK). Design: Ex-vivo. Methods: Corneoscleral buttons from human donors were loaded onto an artificial anterior chamber connected to a column of balanced salt solution. A surgeon-in-training learned to perform DALK via the BB technique using swept-source microscope-integrated optical coherence tomography (SS-MIOCT) with heads-up display (HUD). DALK procedures were performed at 6 different IOPs (5, 10, 15, 20, 30, or 40 mm Hg; n = 6 per group) in a randomized fashion, with the surgeon-in-training masked to the pressure and guided by SS-MIOCT with HUD. For a subset of corneas within each pressure group, DALK was performed on matching donor tissue at a control IOP. BB diameter was recorded, and a diameter exceeding the trephine diameter was considered optimal. Results: Wilcoxon rank sum test showed a difference in BB diameter among the different pressure groups (mean ± SD of 7.75 ± 1.60, 8.33 ± 1.99, 10.9 ± 0.92, 9.08 ± 1.07, 6.67 ± 3.33, and 3.42 ± 3.77 mm in the 5, 10, 15, 20, 30, and 40 mm Hg groups, respectively; P = 0.0014). Per Tukey test, this difference was attributable to comparisons between the 40 mm Hg group and the 5, 10, 15, or 20 mm Hg groups (P = 0.04, 0.02, 0.0001, 0.004, respectively). Conclusions: In this ex-vivo model of DALK, the BB technique guided by SS-MIOCT with HUD yielded bubbles of optimal diameters only at physiologic pressures (10-20 mm Hg). Extremely high IOP (40 mm Hg) resulted in BBs of significantly smaller diameter than BBs obtained at physiologic and low (5 mm Hg) IOPs.Keywords
This publication has 27 references indexed in Scilit:
- Needle Depth and Big-Bubble Success in Deep Anterior Lamellar KeratoplastyCornea, 2016
- Live volumetric (4D) visualization and guidance of in vivo human ophthalmic surgery with intraoperative optical coherence tomographyScientific Reports, 2016
- Optimising deep anterior lamellar keratoplasty (DALK) using intraoperative online optical coherence tomography (iOCT)British Journal of Ophthalmology, 2014
- Long-term comparison of full-bed deep anterior lamellar keratoplasty and penetrating keratoplasty in treating keratoconusJournal of Zhejiang University-SCIENCE B, 2013
- Long-term Results of Deep Anterior Lamellar versus Penetrating KeratoplastyOphthalmology, 2012
- Visual acuity outcomes after deep anterior lamellar keratoplasty: a case-control studyBritish Journal of Ophthalmology, 2010
- Recipient Risk Factors for Graft Failure in the Cornea Donor StudyOphthalmology, 2009
- Comparison of Three Different Techniques of Corneal Transplantation for KeratoconusAmerican Journal of Ophthalmology, 2008
- Big-bubble technique to bare Descemet's membrane in anterior lamellar keratoplastyJournal of Cataract & Refractive Surgery, 2002
- Ten-year postoperative results of penetrating keratoplastyOphthalmology, 1998