Variational Mode Decomposition (VMD) Based Method of Leakage Locating in Water Delivery Lines

Authors:
  • WSWu Shanshan
    Wu Shanshan
  • HGHu Guobing
    Hu Guobing
  • GBGu Bing
    Gu Bing
  • DNDing Ning
    Ding Ning
  • YGYu Guiyang
    Yu Guiyang

Abstract
A method based on variational mode decomposition (VMD) to locate the leak point in water delivery lines is proposed. The leakage acoustic signals sampled by two sensors situated at both the ends of the pipe are processed using VMD to remove the noise. In order to locate the position of the leak, cross-correlation of the filtered leakage acoustic signal is calculated to estimate the time delay. The VMD method is more robust because it can estimate the modes adaptively, and its detection and decomposition properties are independent of the harmonic frequencies. Simulations show that the VMD method can remove noise while preserving the essential characteristics of the acoustic signal. The precision of the location can be improved by calculating the cross-correlation of the filtered leakage acoustic signal.