High-resolution cone-beam computed tomography: a potential tool to improve atraumatic electrode design and position
- 11 January 2012
- journal article
- Published by Taylor & Francis in Acta Oto-Laryngologica
- Vol. 132 (4) , 361-368
Abstract
Conclusions: Flat-panel cone-beam computed tomography (CBCT) is able to assess the trajectory of the implanted cochlear implant (CI) array. This is essential to determine specific effects of electrode design and surgical innovations on outcomes in cochlear implantation. CBCT is a non-invasive approach yielding similar data to histopathological analyses, with encouraging potential for use in surgical, clinical and research settings. Objectives: To examine the fidelity of CBCT imaging and custom 3D visualization in characterizing CI insertion in comparison to gold standard, histopathological examination. Methods: Eleven human temporal bones were implanted with the ‘Straight Research Array’ (SRA). Post-insertion, they were imaged with a prototype mobile C-arm for intraoperative CBCT. Post-acquisition processing of low-dose CBCT images produced high-resolution 3D volumes with sub-millimetre spatial resolution (isotropic 0.2 mm3 voxels). The bones were resin impregnated and sectioned for light microscopic examination. Dimensional electrode characteristics visible in section images were compared with corresponding CBCT images by independent observers. Results: Overall, CBCT demonstrated adequate resolution to detect: 1) scala implanted; 2) kinking; 3) number of intracochlear contacts; 4) appropriate ascension of the array; and overall confirms ideal insertion. CBCT did not demonstrate adequate resolution to detect reversal of electrode contacts or basilar membrane rupture.Keywords
This publication has 21 references indexed in Scilit:
- Low-Dose Temporal Bone CT in Infants and Young Children: Effective Dose and Image QualityAmerican Journal of Neuroradiology, 2011
- Evaluation of the hybrid‐L24® electrode using microcomputed tomographyThe Laryngoscope, 2011
- Anatomic verification of a novel method for precise intrascalar localization of cochlear implant electrodes in adult temporal bones using clinically available computed tomographyThe Laryngoscope, 2010
- Evolution of Cochlear Implant Arrays Result in Changes in Behavioral and Physiological Responses in ChildrenOtology & Neurotology, 2009
- Intraoperative use of cone‐beam computed tomography in a cadaveric ossified cochlea modelOtolaryngology–Head and Neck Surgery, 2009
- Imaging of electrode position in relation to electrode functioning after cochlear implantationEuropean Archives of Oto-Rhino-Laryngology, 2009
- Assessment of intracochlear electrode position and correlation with behavioural thresholds in CII and 90K cochlear implantsActa Oto-Laryngologica, 2008
- Scalar Localization of the Electrode Array After Cochlear ImplantationOtology & Neurotology, 2007
- High resolution micro-CT scanning as an innovatory tool for evaluation of the surgical positioning of cochlear implant electrodesActa Oto-Laryngologica, 2006
- Cochlear Implant Surgery at 12 Months of Age or YoungerThe Laryngoscope, 2004