Plethysmographic dynamic indices predict fluid responsiveness in septic ventilated patients
Top Cited Papers
- 29 March 2007
- journal article
- research article
- Published by Springer Nature in Intensive Care Medicine
- Vol. 33 (6) , 993-999
Abstract
Objectives In septic patients, reliable non-invasive predictors of fluid responsiveness are needed. We hypothesised that the respiratory changes in the amplitude of the plethysmographic pulse wave (ΔPPLET) would allow the prediction of changes in cardiac index following volume administration in mechanically ventilated septic patients. Design Prospective clinical investigation. Setting An 11-bed hospital medical intensive care unit. Patients Twenty-three deeply sedated septic patients mechanically ventilated with tidal volume ≥ 8 ml/kg and equipped with an arterial catheter and a pulse oximetry plethysmographic sensor. Interventions Respiratory changes in pulse pressure (ΔPP), ΔPPLET and cardiac index (transthoracic Doppler echocardiography) were determined before and after volume infusion of colloids (8 ml/kg). Measurements and main results Twenty-eight volume challenges were performed in 23 patients. Before volume expansion, ΔPP correlated with ΔPPLET (r 2 = 0.71, p < 0.001). Changes in cardiac index after volume expansion significantly (p < 0.001) correlated with baseline ΔPP (r 2 = 0.76) and ΔPPLET (r 2 = 0.50). The patients were defined as responders to fluid challenge when cardiac index increased by at least 15% after the fluid challenge. Such an event occurred 18 times. Before volume challenge, a ΔPP value of 12% and a ΔPPLET value of 14% allowed discrimination between responders and non-responders with sensitivity of 100% and 94% respectively and specificity of 70% and 80% respectively. Comparison of areas under the receiver operator characteristic curves showed that ΔPP and ΔPPLET predicted similarly fluid responsiveness. Conclusion The present study found ΔPPLET to be as accurate as ΔPP for predicting fluid responsiveness in mechanically ventilated septic patients.Keywords
This publication has 26 references indexed in Scilit:
- Respiratory variations in pulse oximeter waveform amplitude are influenced by venous return in mechanically ventilated patients under general anaesthesia2007
- Arterial Versus Plethysmographic Dynamic Indices to Test Responsiveness for Testing Fluid Administration in Hypotensive Patients: A Clinical TrialAnesthesia & Analgesia, 2006
- Analysis of the Ear Pulse Oximeter WaveformJournal of Clinical Monitoring and Computing, 2006
- Pulse pressure variations to predict fluid responsiveness: influence of tidal volumeIntensive Care Medicine, 2005
- Superior vena caval collapsibility as a gauge of volume status in ventilated septic patientsIntensive Care Medicine, 2004
- 2001 SCCM/ESICM/ACCP/ATS/SIS International Sepsis Definitions ConferenceIntensive Care Medicine, 2003
- Stroke volume variations for assessment of cardiac responsiveness to volume loading in mechanically ventilated patients after cardiac surgeryIntensive Care Medicine, 2002
- The peripheral pulse wave: Information overlookedJournal of Clinical Monitoring and Computing, 1996
- Principles of Pulse OximetryAnesthesia & Analgesia, 1989
- Controlled Sedation with Alphaxalone-AlphadoloneBMJ, 1974