Diagnostic efficacy of routine contrast-enhanced abdominal CT for the assessment of osteoporosis in the Turkish population
Open Access
- 1 January 2020
- journal article
- research article
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in TURKISH JOURNAL OF MEDICAL SCIENCES
- Vol. 50 (1) , 110-116
Abstract
This study aimed to evaluate the diagnostic efficacy of vertebral Hounsfield unit (HU) values on routine contrast- enhanced abdominal computed tomography (CT) scans for the assessment of osteoporosis using dual-energy X-ray absorptiometry (DXA) T-scores as a reference standard. A total of 111 consecutive patients who underwent contrast-enhanced abdominal CT examination for any indication and DXA within a 6-month period were retrospectively analyzed. The CT attenuation values of trabecular bone in HUs were measured in axial and sagittal planes from lumbar vertebrae 1–4 (L1–L4). The correlation between the DXA T-scores and HU values measured on the CT scans was evaluated by Pearson’s correlation test. Areas under the curves (AUCs) were calculated by receiver operating characteristic analysis for diagnostic proficiency, and threshold values were determined. Paired t-test and Bland–Altman plot test were used to evaluate the correlation between axial and sagittal HU values. There was a strong correlation between the DXA T-scores and HU values of all the lumbar vertebrae (P < 0.001). The highest correlation was for the L3 vertebra; L3 was thus chosen for additional analyses. The mean axial and sagittal L3 attenuations were 133.7 HU and 131.9 HU, respectively. The axial measurements were not significantly different from the sagittal measurements, with a mean difference of 1.8 HU (P > 0.05). The L3 axial CT attenuation threshold for 90% sensitivity was 170 HU and that for 90% specificity was 102 HU for distinguishing osteoporosis from osteopenia and normal bone mineral density (BMD). To distinguish the low BMD group from the normal group, the L3 axial CT attenuation threshold for approximately 90% sensitivity was 102 HU and for 90% specificity was 165 HU. The HUs derived from routine contrast-enhanced abdominal CT scans can be used for the evaluation of osteoporosis, without additional radiation exposure and cost.Keywords
This publication has 16 references indexed in Scilit:
- Comparison of Femoral Neck BMD Evaluation Obtained Using Lunar DXA and QCT With Asynchronous Calibration From CT ColonographyJournal of Clinical Densitometry, 2015
- Intravenous contrast injection significantly affects bone mineral density measured on CTEuropean Radiology, 2014
- Unreported Vertebral Body Compression Fractures at Abdominal Multidetector CTRadiology, 2013
- Opportunistic Screening for Osteoporosis Using Abdominal Computed Tomography Scans Obtained for Other IndicationsAnnals of Internal Medicine, 2013
- Simultaneous screening for osteoporosis at CT colonography: Bone mineral density assessment using MDCT attenuation techniques compared with the DXA reference standardJournal of Bone and Mineral Research, 2011
- A population-based analysis of the post-fracture care gap 1996–2008: the situation is not improvingOsteoporosis International, 2011
- Feasibility of Simultaneous Computed Tomographic Colonography and Fully Automated Bone Mineral Densitometry in a Single ExaminationJournal of Computer Assisted Tomography, 2011
- Fundamentals and pitfalls of bone densitometry using dual-energy X-ray absorptiometry (DXA)Osteoporosis International, 2004
- World-wide Projections for Hip FractureOsteoporosis International, 1997
- Hip fractures in the elderly: A world-wide projectionOsteoporosis International, 1992