Mechanical and Morphological Assessment of an Innovative Textile for Patient Positioning Applications: Comparison to Two Standard Bandage Systems
Open Access
Abstract
In the healthcare environment, bandage systems are versatile medical devices to position and fix patients’ torsos or extremities. In this study, the mechanical and morphological properties of an innovative patient position system, iFix, were assessed and compared to two commercially available bandages. Morphological properties were investigated using a scanning electron microscope (SEM). The iFix bandage showed anisotropic mechanical properties, with a more rigid behavior in the longitudinal direction and a more elastic behavior in the transverse direction. This behavior results from the organization of the fibers visible in the SEM images. All three materials investigated in this study were able to support similar maximum loads. In cases where a rigid fixation of patient limbs or torso is necessary, the authors recommend the usage of iFix. In vivo studies should be carried out to prove safety in a surgical environment before its clinical usage.Keywords
Funding Information
- Österreichische Forschungsförderungsgesellschaft (869710)
This publication has 18 references indexed in Scilit:
- Proper Patient Positioning and Complication Prevention in Orthopaedic SurgeryJournal of Bone and Joint Surgery, 2014
- Biomechanische Charakterisierung von medizinischen Thromboseprophylaxestrümpfen (MTPS)Gefässchirurgie, 2013
- Elastic Multilayer Bandages for Chronic Venous Insufficiency: Features of Our TechniqueAnnals of Vascular Diseases, 2012
- Classification of Compression BandagesDermatologic Surgery, 2008
- Influence of Different Materials in Multicomponent Bandages on Pressure and Stiffness of the Final BandageDermatologic Surgery, 2008
- Classification of Compression Bandages: Practical AspectsDermatologic Surgery, 2008
- Quantitative assessment of relationship between pressure performances and material mechanical properties of medical graduated compression stockingsJournal of Applied Polymer Science, 2007
- Measurement of Lower Leg Compression In Vivo: Recommendations for the Performance of Measurements of Interface Pressure and StiffnessDermatologic Surgery, 2006
- The Use of Pressure Change on Standing as a Surrogate Measure of the Stiffness of a Compression BandageEuropean Journal of Vascular and Endovascular Surgery, 2005
- A Method for Measuring the Dynamic Behavior of Medical Compression Hosiery during WalkingDermatologic Surgery, 2004