Application of a combined system of polycapillary x-ray lens and toroidal mirror in micro-x-ray-absorption fine-structure facility
Authors:
- 1 May 2006
- journal article
- conference paper
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 99 (9) , 094907
Abstract
A micro-x-ray-absorption fine-structure facility based on a monolithic half focusing polycapillary x-ray lens (MHFPXRL), a toroidal mirror, and synchrotron radiation is proposed. The synchrotron radiation is focused by using a combined system of a MHFPXRL and a toroidal mirror. At , the synchrotron radiation beam with a area is first focused into a beam spot with a area by a toroidal mirror. This focused beam is then focused into a focal spot with a diameter by using a MHFPXRL. The gain of power flux density in the focal spot of the combined system is 47 473. The focal distance of the MHFPXRL is . The transmitting extended x-ray-absorption fine-structure (EXAFS) spectrum of Ni foil and the fluorescent EXAFS spectrum of zinc in the zinc hyperaccumulator are measured.
Keywords
This publication has 11 references indexed in Scilit:
- Measurements of energy dependence of properties of polycapillary x-ray lens by using organic glass as a scattererJournal of Applied Physics, 2005
- Microbeam high-resolution x-ray diffraction in strained InGaAlAs-based multiple quantum well laser structures grown selectively on masked InP substratesJournal of Applied Physics, 2005
- Analysis and localization of metal‐ and metalloid‐containing proteins by synchrotron radiation x‐ray fluorescence spectrometryX-Ray Spectrometry, 2004
- Characterization of a polycapillary lens for use in micro‐XANES experimentsX-Ray Spectrometry, 2003
- Polycapillary x‐ray optics: manufacturing status, characterization and the future of the technologyX-Ray Spectrometry, 2003
- Spectral and lateral resolved characterisation of X-ray microbeamsNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2002
- Suitability of polycapillary optics for focusing of monochromatic synchrotron radiation as used in trace level micro-XANES measurementsJournal of Analytical Atomic Spectrometry, 2002
- Interpretation of capillary generated spatial and angular distributions of x rays: Theoretical modeling and experimental verification using the European Synchrotron Radiation Facility Optical beam lineReview of Scientific Instruments, 1998
- Focusing of synchrotron radiation with polycapillary opticsNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 1997
- Micro-distribution of heavy elements in highly inhomogeneous particles generated from μ-beam XRF/XRD analysisNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 1997