Rigid, Complete Annuloplasty Rings Increase Anterior Mitral Leaflet Strains in the Normal Beating Ovine Heart
- 13 September 2011
- journal article
- Published by Wolters Kluwer Health in Circulation
- Vol. 124 (11_suppl_1) , S81-96
Abstract
Annuloplasty ring or band implantation during surgical mitral valve repair perturbs mitral annular dimensions, dynamics, and shape, which have been associated with changes in anterior mitral leaflet (AML) strain patterns and suboptimal long-term repair durability. We hypothesized that rigid rings with nonphysiological three-dimensional shapes, but not saddle-shaped rigid rings or flexible bands, increase AML strains. Sheep had 23 radiopaque markers inserted: 7 along the anterior mitral annulus and 16 equally spaced on the AML. True-sized Cosgrove-Edwards flexible, partial band (n=12), rigid, complete St Jude Medical rigid saddle-shaped (n=12), Carpentier-Edwards Physio (n=12), Edwards IMR ETlogix (n=11), and Edwards GeoForm (n=12) annuloplasty rings were implanted in a releasable fashion. Under acute open-chest conditions, 4-dimensional marker coordinates were obtained using biplane videofluoroscopy along with hemodynamic parameters with the ring inserted and after release. Marker coordinates were triangulated, and the largest maximum principal AML strains were determined during isovolumetric relaxation. No relevant changes in hemodynamics occurred. Compared with the respective control state, strains increased significantly with rigid saddle-shaped annuloplasty ring, Carpentier-Edwards Physio, Edwards IMR ETlogix, and Edwards GeoForm (0.14±0.05 versus 0.16±0.05, P =0.024, 0.15±0.03 versus 0.18±0.04, P =0.020, 0.11±0.05 versus 0.14±0.05, P =0.042, and 0.13±0.05 versus 0.16±0.05, P =0.009), but not with Cosgrove-Edwards band (0.15±0.05 versus 0.15±0.04, P =0.973). Regardless of three-dimensional shape, rigid, complete annuloplasty rings, but not a flexible, partial band, increased AML strains in the normal beating ovine heart. Clinical studies are needed to determine whether annuloplasty rings affect AML strains in patients, and, if so, whether ring-induced perturbations in leaflet strain states are linked to repair failure.Keywords
This publication has 21 references indexed in Scilit:
- Effects of different annuloplasty ring types on mitral leaflet tenting area during acute myocardial ischemiaThe Journal of Thoracic and Cardiovascular Surgery, 2011
- Midterm Outcomes Using the Physio Ring in Mitral Valve Reconstruction: Experience in 492 PatientsThe Annals of Thoracic Surgery, 2005
- Effects of a Saddle Shaped Annulus on Mitral Valve Function and Chordal Force Distribution: An In Vitro StudyAnnals of Biomedical Engineering, 2003
- Effects of papillary muscle position on in-vitro dynamic strain on the porcine mitral valve.2003
- Mitral leaflet geometry perturbations with papillary muscle displacement and annular dilatation: an in-vitro study of ischemic mitral regurgitation.2003
- Surface Strains in the Anterior Leaflet of the Functioning Mitral ValveAnnals of Biomedical Engineering, 2002
- Effect of Annular Shape on Leaflet Curvature in Reducing Mitral Leaflet StressCirculation, 2002
- Annular dilatation increases stress in the mitral valve and delays coaptation: a finite element computer modelCardiovascular Surgery, 1997
- Experimental evaluation of different chordal preservation methods during mitral valve replacementThe Annals of Thoracic Surgery, 1994
- Automatic tracking and digitization of multiple radiopaque myocardial markersComputers and Biomedical Research, 1991