Liver PDFF estimation using a multi-decoder water-fat separation neural network with a reduced number of echoes
Open Access
- 4 April 2023
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 33 (9) , 6557-6568
Abstract
Objective: To accurately estimate liver PDFF from chemical shift-encoded (CSE) MRI using a deep learning (DL)-based Multi-Decoder Water-Fat separation Network (MDWF-Net), that operates over complex-valued CSE-MR images with only 3 echoes. Methods: The proposed MDWF-Net and a U-Net model were independently trained using the first 3 echoes of MRI data from 134 subjects, acquired with conventional 6-echoes abdomen protocol at 1.5 T. Resulting models were then evaluated using unseen CSE-MR images obtained from 14 subjects that were acquired with a 3-echoes CSE-MR pulse sequence with a shorter duration compared to the standard protocol. Resulting PDFF maps were qualitatively assessed by two radiologists, and quantitatively assessed at two corresponding liver ROIs, using Bland Altman and regression analysis for mean values, and ANOVA testing for standard deviation (STD) (significance level: .05). A 6-echo graph cut was considered ground truth. Results: Assessment of radiologists demonstrated that, unlike U-Net, MDWF-Net had a similar quality to the ground truth, despite it considered half of the information. Regarding PDFF mean values at ROIs, MDWF-Net showed a better agreement with ground truth (regression slope = 0.94, R2 = 0.97) than U-Net (regression slope = 0.86, R2 = 0.93). Moreover, ANOVA post hoc analysis of STDs showed a statistical difference between graph cuts and U-Net (p < .05), unlike MDWF-Net (p = .53). Conclusion: MDWF-Net showed a liver PDFF accuracy comparable to the reference graph cut method, using only 3 echoes and thus allowing a reduction in the acquisition times. Clinical relevance statement: We have prospectively validated that the use of a multi-decoder convolutional neural network to estimate liver proton density fat fraction allows a significant reduction in MR scan time by reducing the number of echoes required by 50%. Key Points: • Novel water-fat separation neural network allows for liver PDFF estimation by using multi-echo MR images with a reduced number of echoes. • Prospective single-center validation demonstrated that echo reduction leads to a significant shortening of the scan time, compared to standard 6-echo acquisition. • Qualitative and quantitative performance of the proposed method showed no significant differences in PDFF estimation with respect to the reference technique.Keywords
Funding Information
- FONDECYT (1191710, 1231535, 1191145)
- i-Health Millennium Institute for Intelligent Healthcare Engineering (ICN2021_004)
- National Agency for Research and Development (ANID) / Scholarship Program / DOCTORADO BECAS CHILE/2020 (21210665)
- Anillo PIA (ACT192064)
- ANID FONDECYT Postdoctorado 2019 (3190763)
- Monash University
This publication has 28 references indexed in Scilit:
- Relaxation effects in MRI‐based quantification of fat content and fatty acid compositionMagnetic Resonance in Medicine, 2013
- ISMRM workshop on fat–water separation: Insights, applications and progress in MRIMagnetic Resonance in Medicine, 2012
- Quantitative assessment of liver fat with magnetic resonance imaging and spectroscopyJournal of Magnetic Resonance Imaging, 2011
- In vivo characterization of the liver fat 1H MR spectrumNMR in Biomedicine, 2010
- Chemical shift–based water/fat separation: A comparison of signal modelsMagnetic Resonance in Medicine, 2010
- Robust water/fat separation in the presence of large field inhomogeneities using a graph cut algorithmMagnetic Resonance in Medicine, 2009
- Multiecho water‐fat separation and simultaneous R estimation with multifrequency fat spectrum modelingMagnetic Resonance in Medicine, 2008
- Multiecho reconstruction for simultaneous water‐fat decomposition and T2* estimationJournal of Magnetic Resonance Imaging, 2007
- MRI R2 and R2* mapping accurately estimates hepatic iron concentration in transfusion-dependent thalassemia and sickle cell disease patientsBlood, 2005
- Multicoil Dixon chemical species separation with an iterative least‐squares estimation methodMagnetic Resonance in Medicine, 2003