On-line Removal of Sulfide Interference in Phosphate Determination by Flow Injection Analysis
- 2 March 2006
- journal article
- editorial
- Published by CSIRO Publishing in Environmental Chemistry
- Vol. 3 (1) , 19-25
Abstract
Environmental Context. Effective management of eutrophication and resultant major algal blooms requires accurate assessment of the importance of internal (sediment-based) as well as external, sources of phosphorus to susceptible aquatic ecosystems. The high spatial variability in pore water filterable reactive phosphorus (FRP) necessitates extensive sampling, and rapid flow injection methods overcome many of the difficulties in maintaining sample integrity. A simple flow injection manifold has been developed to prevent major sulfide interference with FRP determination and therefore enable accurate phosphate measurements. Simple on-line sulfide removal using potassium permanganate (KMnO4) was incorporated into a spectrophotometric flow injection (FI) system for phosphate determination using molybdenum blue with ascorbic acid as the reductant. Excess KMnO4 was reduced before the sample zone passed through the detector and the method effectively removed all sulfide interference. Without this removal, sulfide interference caused major errors in filterable reactive phosphorus (FRP) analyses. Some model organic phosphates were tested with the permanganate manifold and there was no conversion to phosphate. With the KMnO4 carrier, the calibration plot was linear over the tested range (0–1000 µg L-1 P), with a detection limit of 38 µg L-1 P. Precision was typically better than 2.5%, based on triplicate injections. FRP determinations on anoxic, estuarine pore water samples were in excellent agreement with the conventional batch method with prior acidification and sparging, but avoided sample pretreatment and the generation of toxic H2S. Samples spiked with phosphate gave recoveries of 93–104%. Given the simplicity of modifying conventional FI manifolds to incorporate the improvements described here, it is recommended that all FRP measurements by FI replace water as the carrier with 0.01 M KMnO4 whenever the presence of sulfide is suspected.Keywords
This publication has 21 references indexed in Scilit:
- The Reduction of Internal Phosphorus Loading Using Alum in Spring Lake, MichiganJournal of Environmental Quality, 2004
- Nitrogen and Phosphorus Flux Rates from Sediment in the Lower St. Johns River EstuaryJournal of Environmental Quality, 2004
- Effect of an Alternating Oxic/Anoxic Regime on a (Freshwater) Yarra River SedimentAustralian Journal of Chemistry, 2003
- Why the phosphorus retention of lakes does not necessarily depend on the oxygen supply to their sediment surfaceLimnology and Oceanography, 2003
- Internal phosphorus loading in Lake RingsjönHydrobiologia, 1999
- Eutrophication: impacts of excess nutrient inputs on freshwater, marine, and terrestrial ecosystemsEnvironmental Pollution, 1999
- Phosphorus Flux between Sediment and Overlying Water in Lake Okeechobee, Florida: Spatial and Temporal VariationsJournal of Environmental Quality, 1998
- In situ measurement of dissolved phosphorus in natural waters using DGTAnalytica Chimica Acta, 1998
- Phosphate exchange across the sediment-water interface when shifting from anoxic to oxic conditions an experimental comparison of freshwater and brackish-marine systemsBiogeochemistry, 1997
- Phosphorus release in Lake Groβer Müggelsee and its implications for lake restorationHydrobiologia, 1997