Clinical Evaluation of a Prototype Underwear Designed to Detect Urine Leakage From Continence Pads
- 1 November 2015
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Wound, Ostomy & Continence Nursing
- Vol. 42 (6) , 632-639
Abstract
PURPOSE: We evaluated the performance of prototype underwear designed to detect urine leakage from continence pads, their acceptability to users, and their effect on health-related quality of life and psychosocial factors. DESIGN: Prototype product evaluation. SUBJECTS AND SETTING: Participants were 81 women with an average age of 67 years (range, 32-98 years) recruited between October 2010 and February 2012 from outpatient clinics, general practice surgeries, community continence services, and through charities and networks. METHODS: The TACT3 project developed and manufactured a prototype undergarment designed to alert the wearer to a pad leak before it reaches outer clothing or furniture. The study was conducted in 2 stages: a pilot/feasibility study to assess general performance and a larger study to measure performance, acceptability to users, health-related quality of life, and psychosocial impact. Participants were asked to wear the prototype underwear for a period of 2 weeks, keeping a daily diary of leakage events for the first 7 days. They also completed validated instruments measuring lower urinary tract symptoms, health-related quality of life, and psychosocial impact. RESULTS: On average, 86% of the time participants were alerted to pad leakage events. More than 90% thought the prototype underwear was "good" or "OK" and that it would or could give them more confidence. Mean scores for the International Consultation on Incontinence Questionnaire-Urinary Incontinence Short Form indicated no change in the level of symptoms reported before or after the intervention, and no significant changes in health-related quality of life status occurred, except improvement in for travel restrictions. Evaluation via the Psychosocial Impact of Assistive Devices Scale also indicated a positive impact. CONCLUSION: The prototype underwear evaluated in this study was effective and acceptable for 5 out of every 10 wearers. Findings also suggest that the prototype underwear is suitable for women of all ages, dress sizes, and continence severity.Keywords
This publication has 13 references indexed in Scilit:
- Urinary Incontinence: A Vibration Alert System for Detecting Pad OverflowAssistive Technology, 2011
- Systematic review of the management of incontinence and promotion of continence in older people in care homes: descriptive studies with urinary incontinence as primary focusJournal of Advanced Nursing, 2010
- Absorbent products for incontinence: ‘treatment effects’ and impact on quality of lifeJournal of Clinical Nursing, 2007
- “It can always happen”: The impact of urinary incontinence on elderly men and womenScandinavian Journal of Primary Health Care, 2006
- ICIQ: A brief and robust measure for evaluating the symptoms and impact of urinary incontinenceNeurourology and Urodynamics, 2004
- Measuring the severity of stress urinary incontinence using the Incontinence Impact QuestionnaireNeurourology and Urodynamics, 2003
- The Psychosocial Impact of Assistive Devices Scale (PIADS): Translation and preliminary psychometric evaluation of a Canadian–French versionQuality of Life Research, 2002
- Development of a scale to measure the psychosocial impact of assistive devices: lessons learned and the road aheadDisability and Rehabilitation, 2002
- Urinary Incontinence in Women and the Effects on their LivesScandinavian Journal of Primary Health Care, 1992
- Toward the development of consumer-based criteria for the evaluation of assistive devicesJournal of Rehabilitation Research and Development, 1990