New Bone Formation around Implants Inserted on Autologous and Xenografts Irradiated or not with IR Laser Light: A Histomorphometric Study in Rabbits
Open Access
- 1 June 2013
- journal article
- research article
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 24 (3) , 218-223
Abstract
Use of biomaterials and light on bone grafts has been widely reported. This work assessed the influence of low-level laser therapy (LLLT) on bone volume (BV) and bone implant contact (BIC) interface around implants inserted in blocks of bovine or autologous bone grafts (autografts), irradiated or not, in rabbit femurs. Twenty-four adult rabbits were divided in 8 groups: AG: autograft; XG: xenograft; AG/L: autograft + laser; XG/L: xenograft + laser; AG/I: autograft + titanium (Ti) implant; XG/I: xenograft + Ti implant; AG/I/L: autograft + Ti implant + laser; and XG/I/L: xenograft + Ti implant + laser. The animals received the Ti implant after incorporation of the grafts. The laser parameters in the groups AG/L and XG/L were λ=780 nm, 70 mW, CW, 21.5 J/cm 2 , while in the groups AG/I/L and XG/I/L the following parameters were used: λ=780 nm, 70 mW, 0.5 cm 2 (spot), 4 J/cm 2 per point (4), 16 J/cm 2 per session, 48 h interval × 12 sessions, CW, contact mode. LLLT was repeated every other day during 2 weeks. To avoid systemic effect, only one limb of each rabbit was double grafted. All animals were sacrificed 9 weeks after implantation. Specimens were routinely stained and histomorphometry carried out. Comparison of non-irradiated and irradiated grafts (AG/L versus AG and XG/L versus XG) showed that irradiation increased significantly BV on both grafts (p=0.05, p=0.001). Comparison between irradiated and non-irradiated grafts (AG/I/L versus AG/I and XG/I/L versus XG/I) showed a significant (p=0.02) increase of the BIC in autografts. The same was seen when xenografts were used, without significant difference. The results of this investigation suggest that the use of LLLT is effective for enhancing new bone formation with consequent increase of bone-implant interface in both autologous grafts and xenografts.Keywords
This publication has 15 references indexed in Scilit:
- Morbidity after Chin Bone Harvesting – A Retrospective Long‐Term Follow‐Up StudyClinical Implant Dentistry and Related Research, 2009
- Does the Use of Laser Photobiomodulation, Bone Morphogenetic Proteins, and Guided Bone Regeneration Improve the Outcome of Autologous Bone Grafts? An in Vivo Study in a Rodent ModelPhotomedicine and Laser Surgery, 2008
- Bone repair following bone grafting hydroxyapatite guided bone regeneration and infra-red laser photobiomodulation: a histological study in a rodent modelLasers in Medical Science, 2008
- Infrared Laser Light Further Improves Bone Healing When Associated with Bone Morphogenetic Proteins and Guided Bone Regeneration: An in Vivo Study in a Rodent ModelPhotomedicine and Laser Surgery, 2008
- Influence of low‐level laser treatment on bone regeneration and osseointegration of dental implants following sinus augmentation: An experimental study on sheepClinical Oral Implants Research, 2007
- Infrared Laser Photobiomodulation (λ 830 nm) on Bone Tissue Around Dental Implants: A Raman Spectroscopy and Scanning Electronic Microscopy Study in RabbitsPhotomedicine and Laser Surgery, 2007
- Laser Therapy Improves Healing of Bone Defects Submitted to Autologus Bone GraftPhotomedicine and Laser Surgery, 2006
- Molecular Structure of the Bony Tissue after Experimental Trauma to the Mandibular Region followed by Laser TherapyPhotomedicine and Laser Surgery, 2004
- Effect of 830-nm Laser Light on the Repair of Bone Defects Grafted with Inorganic Bovine Bone and Decalcified Cortical Osseous MembraneJournal of Clinical Laser Medicine & Surgery, 2003
- Osseointegration of endosseous ceramic implants after postoperative low‐power laser stimulation: an in vivo comparative studyClinical Oral Implants Research, 2003