Feasibility of a multigroup Boltzmann–Fokker–Planck solution for electron beam dose calculations
Authors:
Open Access
- 24 January 2023
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-21
Abstract
Legacy nuclear-reactor Boltzmann solvers start clinical deployment as an alternative to Monte Carlo (MC) codes and Fermi–Eyges semiemprical models in radiation oncology treatment planning. Today’s certified clinical solvers are limited to photon beams. In this paper, ELECTR, a state-of-the-art multigroup electron cross sections generation module in NJOY is presented and validated against Lockwood’s calorimetric measurements, EGS-nrc and GEANT-4 for 1–20 MeV unidirectional electron beams. The nuclear-reactor DRAGON-5 solver is upgraded to access the library and solve the Boltzmann–Fokker–Planck (BFP) equation. A variety of heterogeneous radiotherapy and radiosurgery phantom configurations were used for validation purpose. Case studies include a thorax benchmark, that of a typical breast Intra-Operative Radiotherapy and a high-heterogeneity patient-like benchmark. For all beams, $$100\%$$ of the water voxels satisfied the American Association of Physicists in Medicine accuracy criterion for a BFP-MC dose error below $$2\%$$ . At least, $$97.0\%$$ of adipose, muscle, bone, lung, tumor and breast voxels satisfied the $$2\%$$ criterion. The average BFP-MC relative error was about $$0.56\%$$ for all voxels, beams and materials combined. By irradiating homogeneous slabs from $$Z=1$$ (hydrogen) to $$Z=99$$ (einsteinium), we reported performance and defects of the CEPXS mode [US. Sandia National Lab., SAND-89-1685] in ELECTR for the entire periodic table. For all Lockwood’s benchmarks, NJOY-DRAGON dose predictions are within the experimental data precision for $$98\%$$ of voxels.
Keywords
Funding Information
- Natural Sciences and Engineering Research Council of Canada (CREATE-481695-2016, CREATE-481695-2016)
- Canada First Research Excellence Fund TransMedTech Institute (094382, 094382)
This publication has 94 references indexed in Scilit:
- Dosimetric accuracy and clinical quality of Acuros XB and AAA dose calculation algorithm for stereotactic and conventional lung volumetric modulated arc therapy plansRadiation Oncology, 2013
- Experimental verification of the Acuros XB and AAA dose calculation adjacent to heterogeneous media for IMRT and RapidArc of nasopharygeal carcinomaMedical Physics, 2013
- Clinical validation of the Acuros XB photon dose calculation algorithm, a grid-based Boltzmann equation solverActa Oncologica, 2011
- Feasibility of a Multigroup Deterministic Solution Method for Three-Dimensional Radiotherapy Dose CalculationsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2008
- Accelerator physics at LEPReports on Progress in Physics, 2000
- The nature of transport calculations used in radiation oncologyTransport Theory and Statistical Physics, 1997
- On the accuracy of the Fokker–Planck and Fermi pencil beam equations for charged particle transportMedical Physics, 1996
- Electron-photon Monte Carlo calculations: The ETRAN codeInternational Journal of Radiation Applications and Instrumentation. Part A. Applied Radiation and Isotopes, 1991
- On a numerical approach of the pencil beam modelPhysics in Medicine & Biology, 1985
- Theoretical electron-atom elastic scattering cross sectionsAtomic Data and Nuclear Data Tables, 1975