Energy Conservation Potential of Economizer Controls Using Optimal Outdoor Air Fraction Based on Field Study
Open Access
- 24 September 2020
- Vol. 13 (19) , 5038
Abstract
In commercial buildings, HVAC systems are becoming a primary driver of energy consumption, which already account for 45% of the total building energy consumption. In the previous literature, researchers have studied several energy conservation measures to reduce HVAC system energy consumption. One of the effective ways is an economizer in air-handling units. Therefore, this study quantified the impact of the outdoor air fraction by economizer control type in cooling system loads based on actual air-handling unit operation data in a hospital. The optimal outdoor air fraction and energy performance for economizer control types were calculated and analyzed. The result showed that economizer controls using optimal outdoor air fraction were up to 45% more efficient in cooling loads than existing HVAC operations in the hospital. The energy savings potential was 6–14% of the differential dry-bulb temperature control, 17–27% of the differential enthalpy control, 8–17% of the differential dry-bulb temperature and high-limit differential enthalpy control, and 16–27% of the differential enthalpy and high-limit differential dry-bulb temperature control compared to the no economizer control. The result of this study will contribute to providing a better understanding of economizer controls in the hospital when the building operates in hot-humid climate regions.Keywords
Funding Information
- National Research Foundation of Korea (2020R1C1C1010801)
This publication has 28 references indexed in Scilit:
- Model predictive control for supervising multiple rooftop unit economizers to fully leverage free cooling energy resourceApplied Energy, 2020
- Development and validation of an intelligent load control algorithmEnergy and Buildings, 2017
- The coupled effects of personalized occupancy profile based HVAC schedules and room reassignment on building energy useEnergy and Buildings, 2014
- Variable air volume air-conditioning experiment system with advanced controlsIndoor and Built Environment, 2014
- Analysis of energy saving potential of air-side free cooling for data centers in worldwide climate zonesEnergy and Buildings, 2013
- Air handling unit supply air temperature optimal control during economizer cyclesEnergy and Buildings, 2012
- Determination of free cooling potential: A case study for İstanbul, TurkeyApplied Energy, 2011
- A new operating strategy for economizer dampers of VAV systemEnergy and Buildings, 2008
- Thermal mass and night ventilation as passive cooling design strategyRenewable Energy, 2001
- Effectiveness of mass and night ventilation in lowering the indoor daytime temperatures. Part I: 1993 experimental periodsEnergy and Buildings, 1998