Two Methods of Hemodynamic and Volume Status Assessment in Critically Ill Patients
- 22 April 2014
- journal article
- research article
- Published by SAGE Publications in Journal of Intensive Care Medicine
- Vol. 31 (2) , 113-117
Abstract
The invasive nature and potential complications associated with pulmonary artery (PA) catheters (PACs) have prompted the pursuit of less invasive monitoring options. Before implementing new hemodynamic monitoring technologies, it is important to determine the interchangeability of these modalities. This study examines monitoring concordance between the PAC and the arterial waveform analysis (AWA) hemodynamic monitoring system. Critically ill patients undergoing hemodynamic monitoring with PAC were simultaneously equipped with the FloTrac AWA system (both from Edwards Lifesciences, Irvine, California). Data were concomitantly obtained for hemodynamic variables. Bland-Altman methodology was used to assess CO measurement bias and κ coefficent to show discrepancies in intravascular volume. Significant measurement bias was observed in both CO and intravascular volume status between the 2 techniques (mean bias, −1.055 ± 0.263 liter/min, r = 0.481). There was near-complete lack of agreement regarding the need for intravenous volume administration (κ = 0.019) or the need for vasoactive agent administration (κ = 0.015). The lack of concordance between PAC and AWA in critically ill surgical patients undergoing active resuscitation raises doubts regarding the interchangeability and relative accuracy of these modalities in clinical use. Lack of awareness of these limitations can lead to errors in clinical decision making when managing critically ill patients.Keywords
This publication has 19 references indexed in Scilit:
- Complications Associated with Pulmonary Artery Catheters: A Comprehensive Clinical ReviewScandinavian Journal of Surgery, 2009
- Intensivist Use of Hand-Carried Ultrasonography to Measure IVC Collapsibility in Estimating Intravascular Volume Status: Correlations with CVPJournal of the American College of Surgeons, 2009
- Cardiac Output Measurement in Patients Undergoing Liver Transplantation: Pulmonary Artery Catheter Versus Uncalibrated Arterial Pressure Waveform AnalysisAnesthesia & Analgesia, 2008
- Cardiac Output Measured by a New Arterial Pressure Waveform Analysis Method Without Calibration Compared With Thermodilution After Cardiac SurgeryJournal of Cardiothoracic and Vascular Anesthesia, 2007
- Comparison of FloTrac™ cardiac output monitoring system in patients undergoing coronary artery bypass grafting with pulmonary artery cardiac output measurementsEuropean Journal of Anaesthesiology, 2007
- Exploring measurement biases associated with esophageal Doppler monitoring in critically ill patients in intensive care unitAnnals of Thoracic Medicine, 2007
- A pilot assessment of the FloTracTM cardiac output monitoring systemIntensive Care Medicine, 2006
- LETTERS TO THE EDITOR2005
- Minimally invasive hemodynamic monitoring for the intensivist: Current and emerging technologyCritical Care Medicine, 2002
- The Effectiveness of Right Heart Catheterization in the Initial Care of Critically III PatientsJAMA, 1996