Abstract
This study presents a geometric deformable model‐based segmentation approach to segmentation of the intima and media‐adventitial (MA) borders in sequential intravascular ultrasound (IVUS) images. The initial estimation of the vessel borders was done manually only for the first frame of each sequence. After the border initialisation, pre‐processing including edge preservation, noise reduction, and dead zone preservation was successively performed on each IVUS frame. To improve segmentation performance, the image masks were determined preliminarily by local binary pattern‐based mask initialisation. Then, the inner and outer borders were approximated using a modified distance regularised level set evolution model. The results showed superior performance of the suggested approach for estimating intima and MA layers from the IVUS images. The corresponding correlation coefficients of area, vessel perimeter, maximum vessel diameter, and maximum lumen diameter were r = 0.782, r = 0.716, r = 0.956, and r = 0.874 for the 20 MHz images, respectively, and r = 0.990, r = 0.995, r = 0.989, and r = 0.996 for the 45 MHz images, respectively. In addition, linear regression analysis indicated that the manual segmentation had significantly high similarity at r > 0.967 and r > 0.993 for 20 and 45 MHz images, respectively.Keywords
This publication has 25 references indexed in Scilit:
- Segmentation of the luminal border in intravascular ultrasound B-mode images using a probabilistic approachMedical Image Analysis, 2013
- Automatic segmentation of calcified plaques and vessel borders in IVUS imagesInternational Journal of Computer Assisted Radiology and Surgery, 2008
- Intravascular ultrasound image segmentation: a three-dimensional fast-marching method based on gray level distributionsIEEE Transactions on Medical Imaging, 2006
- Multi-agent segmentation of IVUS imagesPattern Recognition, 2004
- Comparison of texture analysis methods for the characterization of coronary plaques in intravascular ultrasound imagesComputerized Medical Imaging and Graphics, 2000
- Segmentation of 3D intravascular ultrasonic images based on a random field modelUltrasound in Medicine & Biology, 2000
- Tissue characterization in intravascular ultrasound imagesIEEE Transactions on Medical Imaging, 1998
- Automatic segmentation of intravascular ultrasound images: A texture-based approachAnnals of Biomedical Engineering, 1997
- Automated morphometry of coronary arteries with digital image analysis of intravascular ultrasoundAmerican Heart Journal, 1997
- Morphometric analysis in three-dimensional intracoronary ultrasound: An in vitro and in vivo study performed with a novel system for the contour detection of lumen and plaqueAmerican Heart Journal, 1996