Abstract
Distributed temperature sensing (DTS) is a fiber-optic technology that provides continuous temperature profiles along the length of a well. When placing the fiber inside a coiled tubing (CT), one can monitor the temperature evolution while pumping, as well as during a shut-in period. This evolution, in turn, yields some indications about the fluid placement performance or zonal coverage. So far, interpretation of such DTS traces has mostly been qualitative. The work presented here demonstrates how DTS data can be used, coupled with an inversion algorithm and a forward model of fluid injection into a reservoir, to quantify the intake profile of treatment fluid along the wellbore. Recent field cases of matrix acidizing treatments in carbonate reservoirs are analyzed to illustrate the workflow and how it may yield valuable information.Keywords
This publication has 4 references indexed in Scilit:
- Optimization of Stimulation Treatments in Naturally Fractured Carbonate Formations through Effective Diversion and Real-Time Analysis2010
- Correlating equations for natural convection heat transfer between horizontal circular cylindersInternational Journal of Heat and Mass Transfer, 1976
- Interpretation of Temperature Profiles in Water-Injection WellsJournal of Petroleum Technology, 1975
- Temperature Logging In Injection Wells1972